Warranty period: limited 1 year from date of purchase.
SPECIFICATIONS
WARRANTY
FCC ID: 2AMY9PS700
Qolsys warrants to the original purchaser of this product that for the warranty
period, this product will be free from material defects in materials and workmanship.
The foregoing warranty is subject to the proper installa�on, opera�on and
maintenance of the product in accordance with installa�on instruc�ons and the
opera�ng manual supplied to customer.
Warranty claims must be made by customer in wri�ng within 30 days of the
manifesta�on of a problem. Qolsys’ sole obliga�on under the foregoing warranty is
to repair, replace or correct any such defect that was present at the �me of delivery
or during the warranty period. The warranty does not extend to consequen�al or
incidental damage to other products that may be used with this product. For inquiry
and customer service, email [email protected].
All brand names shown are trademarks of their respec�ve owners.
Interoperability with Z-Wave devices
A Z-Wave network can integrate devices from various classes of products, and
these devices can be made by different manufacturers. The product introduced
in this instruc�on manual has a Z-Wave cer�fica�on which allows such an
interoperability.
IC: 22968-PS700
This device complies with Part 15 of the FCC Rules and with RSS of Industry
Canada. Opera�on is subject to the following two condi�ons:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired opera�on.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploita�on est autorisée aux deux condi�ons
suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'u�lisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est suscep�ble d'en comprome�re le fonc�onnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Z-Wave is a registered trademark of Silicon Labs.
Model
PS700
Input power
120 VAC, 60 Hz.
908.4/916 MHz.
Max output loading 900W incandescent, 200W CFL/LED, ½ horsepower motor
and 15A, 1800W resis�ve load
Radio frequency
279� Outdoor line of sight
Wireless range
32°F - 104°F (0°C - 40°C)
Normal opera�ng
temperature
FOR INDOOR USE ONLY
Associa�on:
ADVANCED CONFIGURATION
Configurable Parameter Se�ngs: If your controller supports Z-Wave configurable
parameters, the following se�ngs can be modified.
Depending on the capability of your controller or gateway so�ware, the following
simple to advanced opera�ons can be performed. Please refer to the controller's or
gateway manual for details.
IQ Outlet supports Group 1 for lifeline communica�on and Group 2
- You can associate five Z-Wave devices to Group 1.
- Lifeline associa�on only supports the "manual reset" event.
- For instruc�ons on how to “set lifeline associate”, please refer to your controller/
gateway instruc�ons.
- You can associate five Z-Wave devices to Group 2.
- The devices in Associa�on Group 2 can be controlled (on/off) by single pressing
the bu�on using Basic Set
LED Mode Indicator
0
1
4
When value = 0, the LED indicator will be
OFF when the connected appliance is
ON, and the LED indicator will be ON
when the connected appliance is OFF.
If value = 1, the LED indicator will be OFF
when the connected appliance is OFF,
and the LED indicator will be ON when
the connected appliance is ON.
If value = 2, the LED indicator will be
always OFF regardless of the load status.
#
3
0
1
Descrip�on
Parameters
Values
Default Bytes
NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifica�ons or changes to this equipment. Such modifica�ons or
changes could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protec�on against harmful interference in a residen�al
installa�on. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruc�ons, may cause harmful
interference to radio communica�ons. However, there is no guarantee that
interference will not occur in a par�cular installa�on. If this equipment does cause
harmful interference to radio or television recep�on, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separa�on between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
FCC Compliance Statement (Products subject to Part 15)
Supplier’s Declara�on of Conformity
47 CFR 2.1077 Compliance Informa�on
This device complies with part 15 of the FCC rules. Opera�on is subject to the
following two condi�ons: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired opera�on.
Responsible Party – US Contact Informa�on
Qolsys, Inc.
1900 The Alameda Suite 420
San Jose, CA 95126
United States
Model: PS700
Energy monitoring
repor�ng interval
0 = Disable energy monitoring (default)
1 - 255 = Repor�ng interval (minutes)
SUPPORTED COMMAND CLASSES
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_METER
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SCENE_ACTIVATION
COMMAND_CLASS_SCENE_ACTUATOR_CONF
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_INDICATOR
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_APPLICATION_STATUS
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
v2
v2
v6
v4
v1
v1
v2
v3
v3
v2
v3
v2
v1
v3
v1
v1
v1
v1
v5
Descrip�on
Version Security Class
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2