Appendix 1: Reporting codes
Appendix 1: Reporting codes
The following tables contain Contact ID and Automatic SIA format reporting codes. See "[308] Event Reporting" on page 116
for event reporting codes.
Contact ID
Each of the digits indicate specific information about the signal. For example, if zone 1 is an entry/exit point, the event code
contains [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the “1” indicates which zone went into alarm.
See "Contact ID and SIA Zone Alarm/Restore Event Codes" on page 250 for code definitions.
SIA Format - Level 2 (Hard Coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Stand-
ard - October 1997. This format sends the account code along with its data transmission. The transmission appears similar to
the following at the receiver:
N ri1 BA 01
N = New Event
ri1 = Partition /Area Identifier
BA = Burglary Alarm
01 = Zone 1
A system event uses the Area Identifier ri00.
Contact ID and SIA Zone Alarm/Restore Event Codes
Section #
Definition
Dialer
Direction*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
Zone Events
[307]
Zone Alarms
A/R
see "Contact ID & SIA Zone Alarm/Restore Event Codes" on
page 255" for details.
[307]
Zone Restores
A/R
[307]
Zone tamper/restore
MA/R
E(3)83-ZZZ / R(3)83-ZZZ
TA-ZZZ / TR-ZZZZ
[307]
Zone fault/restore
MA/R
E(3)8A-ZZZ / R(3)8A-ZZZ
UT-ZZZZ / UJ-ZZZZ
Tamper Events
[308]-[101]
Keypad 1-16 tamper/restore alarm
T/R
E(3)83-(601 -616)
R(3)83-(601 -616)
TA-(0601-0616)
TR-(0601-0616)
[308]-[101]
Siren 1-16 tamper/restore alarm
T/R
E (3)83-(801-816)
R (3)83-(801-816)
TA-(0801-0816)
TR-(0801-0816)
[308]-[101]
Repeater 1-8 tamper/restore alarm
T/R
E(3)83-(901-908)
R (3)83-(901-908)
TA-(0901-0908)
TR-(0901-0908)
[308]-[101]
HSM2108: 8-Zone Expander module #1-30 tamper/restored
T/R
E(3)41-(101-130)
R(3)41-(101-130)
ES-(0101-0130)
EJ-(0101-0130)
[308]-[101]
HSM2208: 8-Output Expander module #1-16 tamper/restored
T/R
E(3)41-(201-216)
R(3)41-(201-216)
ES-(0201-0216)
EJ-(0201-0216)
[308]-[101]
HSM2204: Power Supply-1A (4 high-current outputs) #1-4
tamper/restored
T/R
E(3)41-(601-604)
R(3)41-(601-604)
ES-(0601-0604)
EJ-(0601-0604)
[308]-[101]
HSM2300: Power Supply module #1-4 tamper/restored
T/R
E(3)41-(621-624)
R(3)41-(621-624)
ES-(0621-0624)
EJ-(0621-0624)
[308]-[101]
HSM2955: Audio module tamper/restore
T/R
E(3)41-553
R(3)41-553
ES-0553
EJ-0553
[308]-[101]
HSM3408: 8 I/O Expansion module #1-30 tamper/restored
T/R
E(3)41-(301-330)
R(3)41-(301-330)
ES-(0301-0330)
EJ-(0301-0330)
[308]-[101]
HSM3204CX: Corbus repeater module #1-8 tamper/restored
T/R
E(3)41-(801-808)
R(3)41-(801-808)
ES-(0801-0808)
EJ-(0801-0808)
- 250 -