Section 5: Programming
7/8 – Panel Power Unit Failure/Restore
These reporting codes are transmitted when the power unit fails or is restored.
[302] Panel Events 2
1/2 – Bell Circuit Trouble/Restore
This reporting code is transmitted when a bell trouble condition occurs or is restored on the system. This reporting code is
sent to the System Maintenance call direction group.
3/4 – Telephone Line Trouble and Restore
This reporting code is transmitted when an alarm controller TLM trouble occurs or is restored. The TLM trouble is com-
municated over an unaffected communication path if available.
This reporting code is sent to the System Maintenance call direction group.
5/6 – Auxiliary Power Supply Trouble/Restore
This reporting code is transmitted when an auxiliary voltage supply trouble occurs or is restored. This reporting code is sent
to the System Maintenance call direction group.
7/8 – Overcurrent Trouble/Restore
This reporting code is transmitted when an overcurrent trouble occurs or is restored. Current threshold is 2 amps.
[305] Panel Events 5
3/4 – PGM 2 2-Wire Trouble/Restore
This reporting code is transmitted when a trouble condition on PGM 2, configured as two-wire smoke, occurs or is restored.
This reporting code is sent to the System Maintenance call direction group.
[311] Maintenance Events 1
1/2 – RF Jam Trouble/Restore
Sent when RF jam troubles occur/are restored. The following events cause RF jam troubles:
l
Wireless repeater jamming
l
RF jam
3/4 – Fire Trouble/Restore
Sent when a low sensitivity, tamper or internal fault condition/restore is detected on a wireless smoke detector or supervisory
fault with a hardwired smoke detector.
5 – Cold Start
Sent when power is restored to the alarm system after total power failure. The code is sent after 2 minutes to allow the alarm
controller to stabilize.
6 – Delinquency
When the Delinquency option is off (page 119), this code is transmitted if the alarm system has not been armed for the num-
ber of days programmed in the Delinquency Transmission Delay (page 124).
When the Delinquency option is on, this code is transmitted when no zone activity has been detected on the system for the
number of hours programmed in Delinquency Transmission Delay.
7 – Self Test Trouble
Sent when a self test trouble occurs for an outdoor PIR.
8 – Self Test Trouble Restore
Sent when a self test trouble has been restored for an outdoor PIR.
[312] Maintenance Events 2
1/2 – Installer Lead In/ Lead Out
The Installer Lead In and Lead Out reporting codes are sent when the alarm system enters and exits Installer Programming
respectively.
3/4 – DLS Lead In/Lead Out
The DLS Lead In reporting code is sent:
l
after DLS communication has been successfully established, but before the alarm system calls back the down-
loading computer. This code is only transmitted when call back is enabled.
l
on user-initiated call-up.
The DLS Lead Out reporting code is sent when a DLS session is successfully ended.
- 119 -