Note:
If Double-Call option and Number of Rings to Answer are enabled, either one will work
depending on how the installer calls the alarm system.
[407] SA Access Code
This 6-digit hexadecimal code allows the alarm system to confirm the identity of the downloading
computer.
If the code does not match the computer, the alarm system does not allow uploading/downloading.
Programming the access code as FFFFFF disables SA access.
Once an SA connection is established, multiple attempts to input the correct downloading access
code (programmed in [012]) is allowed.
The operator is allowed three attempts to enter the correct access code. If these attempts are
unsuccessful, the alarm system disconnects and a new attempt must be made.
If cellular or IP paths are used for the SA connection, up to five unsuccessful attempts causes a 1-
hour SA lockout (
).
[410] Automatic DLS/SA Options
[001] – Auto DLS Options
Periodic DLS
ON: Upload/download commands programmed in advance (batch files) are periodically
downloaded to the DLS computer.
See below to program the times and days when this occurs.
Note:
The computer must be waiting for a call in order for this feature to work.
OFF: The alarm system does not periodically call the downloading computer.
DLS on Event Buffer %75 Full
ON: The alarm system automatically calls the downloading computer with DLS when the Event
Buffer 75% full event occurs.
This option is independent of the actual transmission of the Event Buffer 75% full event (the event
does not need to be transmitted for the panel to perform the automatic upload).
The panel first communicates the Event Buffer 75% full event (if enabled) using either PSTN or IP
and then performs the automatic download.
OFF: The alarm system does not automatically call the downloading computer when the Event
Buffer 75% full event occurs.
DLS on Programming Change
ON: When the panel returns to the "Ready to Arm" screen after a programming change, 15 minutes
later the alarm system automatically calls the downloading computer.
OFF: The alarm system does not automatically call the downloading computer when the system
programming changes.
[002] Periodic DLS Days
This section is used to program the number of days between periodic DLS downloads. Valid entries
are from 001 to 255 days.
[003] Periodic DLS Time
This section is used to program the time of day periodic DLS download takes place. Time is in 24-
hour format and the default is 00:00 (midnight).
149