Note:
This feature only works with CID
2 - 4 or 6-Digit System Account Code
ON: The programmable account code in section [310][000] is 6 digits long (used for SIA format).
OFF: The programmable account code in section [310][000] is 4 digits long.
5 - Communicate FTC Events
ON: The alarm system communicates FTC (failure to communicate) events. The FTC Trouble/Restore
reporting code transmission follows the call direction the events are assigned to.
OFF: FTC events are not communicated. FTC Trouble/Restore reporting codes are communicated to
the Maintenance call direction group after the next successful communication.
6 - Not used
[384] Communicator Backup Options
2 - Receiver 2 Backup Option
ON: Receiver 2 backs up Receiver 1. Receiver 2 is only used if an FTC event is detected on Receiver 1.
Receiver 2 uses the same format programmed for Receiver 1.
OFF: Receiver 2 is independent and will communicate if a number and format are programmed.
3 - Receiver 3 Backup Option
ON: Receiver 3 backs up Receiver 2. Receiver 3 is only used if an FTC event is detected on Receiver 2.
Receiver 3 uses the same format programmed for Receiver 2.
OFF: Receiver 3 is independent and will communicate if a number and format are programmed.
Receiver 4 Backup Option
ON: Receiver 4 backs up Receiver 3. Receiver 4 is only used if an FTC event is detected on Receiver 3.
Receiver 4 uses the same format programmed for Receiver 3.
OFF: Receiver 4 is independent and will communicate if a number and format are programmed.
[385] Audio Module Talk\Listen Mask
1- Talk/Listen on Receiver 1
ON: 2-way audio sessions can be initiated over receiver 1.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over
receiver 1.
2- Talk/Listen on Receiver 2
ON: 2-way audio sessions can be initiated over receiver 2.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over
receiver 2.
3-Talk/Listen on Receiver 3
ON: 2-way audio sessions can be initiated over receiver 3.
OFF: Regardless of other 2-way audio programming, 2-way audio sessions cannot be initiated over
receiver 3.
4-Talk/Listen on Receiver 4
ON: 2-way audio sessions can be initiated over receiver 4.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
146