[04] Alternate Communicator Receiver 2
Events are communicated through IP receiver 2.
[05] Alternate Communicator Receiver 3
Events are communicated through cellular receiver 1.
[06] Alternate Communicator Receiver 4
Events are communicated through cellular receiver 2.
To use PSTN as the communications path, program section [300] options 001 through 004 as [01]
PSTN 1.
To use the alternate communicator to establish a communications path, program two of the
receivers (section [300] options 001, 002, 003 or 004) as [03] and [04] for Ethernet, and two of the
receivers as [05] and [06] for cellular.
[301] Phone Number Programming
Section [301] is used to program up to 4 telephone numbers used to communicate with the central
station over PSTN.
[001] The phone number used to communicate with receiver 1
[002] The phone number used to communicate with receiver 2
[003] The phone number used to communicate with receiver 3
[004] The phone number used to communicate with receiver 4
All telephone numbers can be a maximum of 32 digits. Hexadecimal digits may be included to
perform the following functions:
• HEX B ([*] [2] [*]) - to dial "*"
• HEX C ([*] [3] [*]) - to dial "#"
• HEX D ([*] [4] [*]) - for an additional dial tone search, as required by PBX telephone systems.
• HEX E ([*] [5] [*]) - to insert a 2-second pause in the telephone number. This causes a static
delay of 2 seconds before any additional dial tone search in a phone number.
• HEX F ([*] [6] [*]) - represents the end of the Phone Number (everything after F is ignored).
• Pressing [#] in these sections exits and saves the entire phone number.
The alarm system does not attempt to communicate using PSTN if no phone number is
programmed.
[304] Call Waiting Cancel String
Use this section to program a string that, when pressed, disables call waiting on a phone line. Call
waiting cancel is typically *70 in most areas. Dialing this string before a phone number disables call
waiting for the duration of the call.
When this section is programmed and Call Waiting Cancel Options is ON (
), the alarm system dials this string before the phone number. This is only done on the first
dialing attempt for each phone number.
This is a 6-digit field. Fill unused digits with Hex F.