Johnson Controls Ducted Systems

AIR CONDITIONING ACCESSORIES

EBE/EUE Furnace Models

EBE and EUE furnaces are factory equipped with a blower, coil shelf,
and control system for add-on air conditioning and heat pump. The coil
shelf accessory 3500-8981 can be used to replace current and older
EBE and EUE coil shelfs. 

With the factory-installed coil shelf, the coil cavity accepts coils as fol-
lows: 

• Up to 19-1/2 in. in height

• Up to 18-1/4 in. in width

• Up to 20-1/2 in. in depth 

For or coil applications with a height above 19-1/2 in., use extension
cabinet accessory 3500-8602.

HIGH PERFORMANCE BLOWER ACCESSORY 

PACKAGE

All EBE/EUE furnaces are equipped with a blower and control system
to add on air conditioning and heat pumps to specified sizes. If the
requirement is to achieve more airflow or cooling than specified, replace
the blower inside the furnace with accessory blower package 3500-
7911. This accessory blower package delivers air conditioning up to 5
tons. Apply accessory blower package 3500-7911 to EBE and EUE
units (downflow or upflow orientation) to achieve higher airflow. Refer to
the installation instructions packed with the accessory package for more
information.

 FIGURE 3: EBE/EUE Furnace - Location of Components

FILTER

INDOOR COIL
COMPARTMENT

INDOOR COIL

(Not factory installed)

INDOOR COIL SHELF

BLOWER ASSEMBLY

ELECTRIC HEATER
AND CONTROLS
COMPARTMENT

FIELD WIRING
COMPARTMENT

THERMOSTAT
CONNECTIONS

EBE

         (DOWNFLOW CONFIGURATION)

EUE

          (UPFLOW CONFIGURATION)

THERMOSTAT
CONNECTIONS

FIELD WIRING
COMPARTMENT

INDOOR COIL SHELF

INDOOR COIL

(Not factory installed)

INDOOR COIL
COMPARTMENT

BLOWER ASSEMBLY

ELECTRIC HEATER 
AND CONTROLS
COMPARTMENT

A1285-001

NOTICE

EUE furnaces are shipped with the coil shelf in the top orientation.
This is not a defect. For application, turn the unit 180° vertically so
the coil shelf is in the bottom orientation.

NOTICE

If the controls are located at the top of the unit, the furnace is an
upflow furnace and the airflow is forced up through the furnace and
into the airways.

 CAUTION

All areas around the line sets, drain hoses and other openings in the
furnace should be sealed airtight. Use some moldable compound or
caulking to seal the area. Failure to do so may result in loss of per-
formance and premature compressor failure.

!

Summary of Contents for EBE10A

Page 1: ...could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It is also used to alert against unsafe practic...

Page 2: ...f in the reverse order and the blower turns off LIMIT CONTROLS Each element has an automatic limit switch that is wired into the circuit The limit switch shuts off power to that element if the heat ex...

Page 3: ...f the furnace to gain access to the filter See Figure 1 For the upflow furnace the filter is located behind the return air grill adja cent to the furnace closet or any other location in the return air...

Page 4: ...ts downflow or upflow orientation to achieve higher airflow Refer to the installation instructions packed with the accessory package for more information FIGURE 3 EBE EUE Furnace Location of Component...

Page 5: ...5396714 BUM C 0919 Johnson Controls Ducted Systems 5 SECTION V REPAIR PARTS LIST FIGURE 4 EBE Downflow Application...

Page 6: ...reaker 3500 128 3500 128 3500 128 21 Circuit Breaker 1 Required S1 3500 377P A Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A 22 Buss Bar See Note 2 S1 3500 378P S1 3500 378P S1 3500 378P 23...

Page 7: ...S1 02541250000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Required See Note 2 S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss Bar S1 3500 378P S1 3500 378P S1 350...

Page 8: ...5396714 BUM C 0919 8 Johnson Controls Ducted Systems FIGURE 5 EUE Upflow Application...

Page 9: ...500 128 3500 128 3500 128 21 Circuit Breaker 1 Required S1 3500 377P A Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A 22 Buss Bar See Note 2 S1 3500 378P S1 3500 378P S1 3500 378P 23 Ground...

Page 10: ...S1 02541250000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Required S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss Bar S1 3500 378P S1 3500 378P S1 3500 378P 23 Gr...

Page 11: ...with Company promptly after installation This will initiate the warranty period and allow us to contact you should it become necessary You can register your product by returning the Warranty Registra...

Page 12: ...furnace 14 Damages caused by improper parts components or accessories not suitable for use in or with the unit For a list of parts that are known to be compatible reference equipment repair parts lis...

Reviews: