TABLE 6 -
ELECTRICAL DATA – OVERSIZED CONDENSER MOTOR
MODEL # VOLTAGE
COMPRESSOR #1
COMPRESSOR #2
EVAP.
FAN
COND.
FAN
MCA
MAX
FUSE/
CCT. BKR.
AMP
QTY
RLA LRA QTY
RLA LRA HP FLA HP
FLA
DSH120C2
208-
230/3/60
2
@ 16.2
110
3
8.5
5
14
58.95
70
DSH120C4 460/3/60
2
@
7.6
52
3
4.2
5
6.6
27.9
35
DSH120C5 575/3/60
2
@
5.3
38.9
3
3.4
5
5.3 20.63
25
FAN PERFORMANCE
TABLE 7 -
DSH024C – SUPPLY AIR BLOWER PERFORMANCE
SUPPLY
CFM
AVAILABLE EXTERNAL STATIC PRESSURE – IWG
1
0.0
0.1
0.2
0.3
0.4
0.6
0.8
1.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Low Static
Drive
3
Factory Drive + 0.5 HP
Hi-Static Drive + 0.5 HP
600
318
0.03
426
0.04
520
0.06
604
0.08
679
0.10
810
0.14
923
0.19
-
-
700
371
0.04
466
0.06
550
0.08
628
0.10
699
0.13
826
0.18
937
0.23
-
-
800
423
0.06
508
0.08
585
0.10
656
0.13
723
0.15
844
0.20
-
-
-
-
900
476
0.09
552
0.11
622
0.14
688
0.16
751
0.19
866
0.24
-
-
-
-
1000
529
0.11
598
0.14
662
0.18
723
0.20
781
0.23
891
0.29
-
-
-
-
NOTES:
1.
Blower performance includes evaporator coil and 2-inch filters.
2.
At higher evaporator airflows and wet bulb conditions, condensate carry-over may occur. Decrease airflow downward as necessary.
3. Field supplied low static drive.
TABLE 8 -
DSH024C – CONDENSER FAN PERFORMANCE
OUTDOOR
CFM
AVAILABLE EXTERNAL STATIC PRESSURE – IWG
0.0
0.2
0.4
0.6
0.8
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Standard Factory Drive
Hi-Static Drive
1600
461
0.16
573
0.23
675
0.31
767
0.39
849
0.48
TABLE 9 -
DSH036C – SUPPLY AIR BLOWER PERFORMANCE
SUPPLY
CFM
AVAILABLE EXTERNAL STATIC PRESSURE – IWG
1
0.0
0.1
0.2
0.3
0.4
0.6
0.8
1.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Low Static
Drive
3
Factory Drive + 0.75 HP
Hi-Static Drive + 0.75 HP
800
453
0.06
534
0.09
609
0.11
679
0.14
744
0.16
866
0.21
969
0.26 1065 0.33
1000
566
0.13
633
0.16
695
0.19
755
0.21
812
0.24
917
0.30 1016 0.38
-
-
1200
680
0.23
735
0.26
789
0.29
840
0.33
890
0.36
983
0.43 1074 0.50
-
-
1400
792
0.36
841
0.40
887
0.44
932
0.48
977
0.51 1061 0.59
-
-
-
-
1600
906
0.54
948
0.58
990
0.63 1030 0.66 1069 0.71
-
-
-
-
-
-
NOTES:
1.
Blower performance includes evaporator coil and 2-inch filters.
2.
At higher evaporator airflows and wet bulb conditions, condensate carry-over may occur. Decrease airflow downward as necessary.
3. Field supplied low static drive.