7
Installation and Maintenance
(1) Take sufficient protective measures when installing the
outdoor unit.
(2) Make sure the support can withstand at least four times the
unit weight.
(3) The outdoor unit should be installed at least 1 3/16 inch
above the floor in order to install drain joint.(As show
n
in
Fig.18)
(4) For the unit with cooling capacity of 2300W~5000W,
six
expansion screws are needed; for the unit with cooling
capacity of 6000W~8000W,
eight
expansion screws are
needed; for the unit with cooling capacity of
10000W~16000W, 10 expansion screws are needed.
(1) After tightening the screw, pull the power cord slightly to
check if it is firm.
(2) Never cut the power connection wire to prolong or shorten
the distance.
(1) The through-wall height of
condensate
hose shouldn't be
higher than the outlet pipe hole of indoor unit.(As show
n
in
Fig.25)
(2) Slant the
condensate
hose slightly downwards. The
condensate
hose can't be curved, raised and fluctuant, etc.(As
show
n
in Fig.26)
Note:
Note:
Note:
The drain hos
can't raise
upwards
gas pipe
Liquid pipe
Liquid
valve
gas valve
Union nut
Pipe joint
Foot holes
Foot holes
2.9 Installation of Outdoor Unit
1. Fix the Support of Outdoor Unit(Install above local
snow line.)
(1) Select installation location according to the house structure.
(2) Fix the support of outdoor unit on the selected location with
expansion screws.
5. Connect Outdoor Electric Wire
(1) Let the connection wire sleeve go through the two holes of
baffle; tighten the connection joint of sleeve and baffle; remove
the wire clip; connect the power connection wire and power
cord to the wiring terminal according to the color; fix them with
screws.(As show
n
in Fig.23)
6. Neaten the Pipes
(1) The pipes should be placed along the wall, bent reasonably
and hidden
if
possibl
e
. Min. semidiameter of bending the pipe
is 3 15/16inch.
(2) If the outdoor unit is higher than the wall hole, you must set
a U-shaped curve in the pipe before pipe goes into the
room, in order to prevent rain from getting into the room.(As
show
n
in Fig.24)
(2) Fix the power connection wire and power cord with wire clip.
(3) Fix the stopper on handle with screw.
2. Install Drain Joint(only for cooling and heating unit)
(1) Connect the outdoor drain joint into the hole on the
chassis.(2) Connect the
condensate
hose into the drain vent.
(As show
n
in Fig.19)
3. Fix Outdoor Unit
(1) Place the outdoor unit on the support.
(2) Fix the foot holes of outdoor unit with bolts.
(As show in Fig.20)
4. Connect Indoor and Outdoor Pipes
(1) Remove the screw on the right handle and valve cover of
outdoor unit and then remove the handle and valve cover.
(As show
n
in Fig.21)
(2) Remove the screw cap of valve and aim the pipe joint at the
bellmouth of pipe.(As show in Fig.22)
(3) Pretighten the union nut
by
hand.
(4) Tighten the union nut with torque wrench .
Hex nut diameter(inch) Tightening torque(ft
·
Ibf)
Φ1/4
11.10~14.75
Φ3/8
22.12~29.50
Φ1/2
33.19~40.56
Φ5/8
44.24~47.94
Φ3/4
51.32~55.31
Refer to the following table for wrench
tightening
:
Fig.18
Fig.19
Fig.20
Fig.21
Fig.22
Fig.23
Fig.24
Fig.25
U-shaped curve
Wall
Drain hose
At least 1 3/16 inch above the floor
Chassis
Outdoor drain joint
Drain hose
Drain vent
Handle
18
、
24K
:
Indoor unit connection
POWER
L1’
S L2’ L2
L2
L1 G
L1
(blue)
white
(blue)
white
red
black (brown)
(brown)
black
(yellow-
green
green)
(yellow-
green
green)
Handle
Valve cover