Check and maintain the ventilating slot once every half years, 
wash and maintain with corresponding disinfection shall 
process once  

every two years are recommended. The filter can expel dust and 
other particles in the air. If it is blocked, the effect of the air 
conditioner will be degraded.Therefore, clean it every another 
two weeks if you use the air conditioner for a long period. 

If the indoor unit is installed in a place with heavy dust, clean the 
filter more often. 

If the stain is heavy and difficult to clean, replace the filter (the 
substitute filter is an optional assembly in the sale). 

Do not replace the power cable without permission. If the power 
cable is damaged, specialized power cable must be used as 
substitute. No not repair the air conditioner without permission. 
The foregoing operations must be performed by the local 
distributor or aftersales service office of manufacturer. 

The edge of some sheet metal assemblies and the fin of the 
condenser are very sharp. Incorrect operation may cause harm. 
Be cautious when cleaning them up.  

Check the air inlet and outlet of the outdoor unit periodically to 
see whether they are blocked by stain or lampblack. 

Contact the distributor or the aftersales service center of 
manufacturer. 

Let the air conditioner run in the air supply mode for about half a 
day, and let its interior be fully dry.  

Switch off the power by the button in remote controller, and then 
cut off the power supply. 

When the main power switch is turned on, a certain extent of 
electric power is consumed even if the air conditioner does not 
run. Turning off the main power switch can save energy. 

Remove the batteries out of the remote controller. 

After the air conditioner has been in service for several seasons, 
foreign substance accumulates inside the unit to an extent 
dependent on the working conditions. Therefore, shut down the 
air conditioner through the ON/OFF button of the remote control-
ler, and then cut off the power supply.  

Check the following issues: 

Check whether the air inlet or outlet of the indoor unit and 
outdoor unit is blocked. Remove foreign substance if any. 

Check whether the ground wire is connected properly. 

Check whether the condensate water is discharged 
normally.(Cooling operation season) 

Check whether the insulation work of refrigerant circuit and  
ventilating duct is on sound status. 

Check whether the installing seat is corroded or rusted. 

8.2  Maintenance & Upkeep Of Outdoor Unit 

8.3  Operation Required Before Leaving The Air 
       Conditioner Idle For A Long Period:  

8.4  Startup After A Long Period Out Of Service 

Startup 

Connect the indoor unit 12 hours after connect the outdoor unit 
to power supply. 

Switch on the power control of remote controller or wire control-
ler, and than startup the air conditioning.    

The following phenomena do not indicate exception of air 
conditioner 

The system does not run. 

After pressing the ON/OFF button, the system does not run 
immediately.  

If the RUN indicator is on, it indicates the air conditioner runs in 
the normal status. 

It does not run immediately because the safety device in the 
system is active to prevent overload. 

Three minutes later, the air conditioner compressor will run 
automatically. 

If the RUN indicator and the Defrost/Preheat indicator are on, it 
indicates you have selected the heating mode. At the beginning 
after startup, since the compressor does not run, the tempera-
ture of the indoor unit is too low. See the chapter headed 
“Cooling/Heating/Supply Air Operation Procedure".  

The indoor unit gives out white aerosol  

This phenomenon may occur when the indoor relative humidity 
is too high and the unit runs in the cooling mode (in a place 
where there is much oil mist or dust).       

If the internal stain of the indoor unit is heavy, the temperature in 
the room will be distributed unevenly. In this case, the interior of 
the indoor unit must be cleaned.  

Contact the local distributor or the aftersales service center of 
manufacturer to inquire about the methods of cleaning the 
indoor unit. This job must be performed by professional 
maintainers. 

This phenomenon may also occur when the air conditioner 
shifts from defrosting operation to heating operation.  

That is because the moist generated by defrosting is expelled as 
steam.  

Noise of air conditioner 

When the air conditioner runs in the cooling, dewetting or 
heating mode automatically, grave continuous sizzles may 
occur.   

That is the sound of flow of refrigerant between the indoor unit 
and the outdoor unit.  

The sizzles may be heard shortly after the unit stops running or 
when the unit runs in the defrost mode. That is the sound raised 
because the refrigerant stops flowing or changes the volume of 
flow.  

Squeak may occur when the air conditioner starts or stops 
running. That is the sound raised because the plastic assem-
blies inflate or deflate when the temperature changes. 

9.

PHENOMENA NOT ATTRIBUTABLE TO

FAULTS OF AIR CONDITIONER

Summary of Contents for 96K Cooling

Page 1: ...Read this manual before installation and operation Make sure that it is well kept for later reference Duct R 410A 50Hz USER S MANUAL YMGFZH096BAN BGX ...

Page 2: ...Split Duct Air Conditioner OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ...

Page 3: ......

Page 4: ...n landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the limit Otherwise oxygen in the room may be affected resulting in ...

Page 5: ...nstall the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out The appliance is not intended for use by young children or infirm persons without supervision DISPOSAL Do not dispose this product as unsor ted municipal waste Collection of such waste sepa rately for special treatment is necessary 2 ELECTRIC SCAFE...

Page 6: ...e outdoor dry wet bulb temperature is 35 C 24 C the heating capacity is measured in a standard environment where the indoor dry wet bulb temperature is 20 C 15 C and the outdoor dry wet bulb temperature is 7 C 6 C and the actual cooling heating capacity changes with the rise fall of the indoor outdoor environment temperature and relative humidity The noise of the unit is measured in the semi noise...

Page 7: ...ater or air with a temperature higher than 50 C to cleanse the filter or panel 8 1 Importants Table 6 1 Inspection before operation Check whether the ground wire is broken or disconnected Check whether the air filter is installed properly If the air conditioner has been out of service for a long period be sure to clean the filter before resuming the service of the air conditioner Cleanse it biweek...

Page 8: ...tatus Check whether the installing seat is corroded or rusted 8 2 Maintenance Upkeep Of Outdoor Unit 8 3 Operation Required Before Leaving The Air Conditioner Idle For A Long Period 8 4 Startup After A Long Period Out Of Service Startup Connect the indoor unit 12 hours after connect the outdoor unit to power supply Switch on the power control of remote controller or wire control ler and than start...

Page 9: ... remote controller or the wire controller fails Operate it after power supply resumes Connect the power supply properly Replace the fuse or check whether electric leakage occurs Check the remote controller or wire controller The set temperature is improper 3 minute protection of the compressor The set temperature is lower than the room temperature during the cooling Or the set temperature is highe...

Page 10: ...g because the set time has expired When it comes to the set time of starting operation of the air conditioner the air conditionerwill start running automati cally and the corresponding display will disappear Symptom When you press ON OFF button the remote controller signal cannot be transmitted Check item The transmitting symbol Ÿ GRHV QRW EOLQN cause Check whether the batteries of remote controll...

Page 11: ...202000171669 ...

Page 12: ......

Page 13: ......

Page 14: ...www johnsoncontrols co m UMGFZHAN 130701 2013 Johnson Controls Inc Johnson Controls reserve theright to change product features without prior notice ...

Reviews: