1083286-UIM-H-0817
14
Johnson Controls Unitary Products
FIGURE 19:
Thermostat Chart - Two Stage HP with Two Stage PSC Furnace
C
24 – Volt Common
Y1
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
THERMOSTAT
W2
Second Stage
Aux. Heat
R
24 – Volt Hot
C
24 – Volt Common
Y
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
* PP32U70124
THERMOSTAT
R
24 – Volt Hot
(Heat XFMR)
24 – Volt Hot
(Cool XFMR)
TWO STAGE
HEAT PUMP
C
24 – Volt Common
R
24 – Volt Hot
Y1
Y2
Second Stage
Compressor
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single
Stage Compressor
TWO STAGE
G
Fan
TWO STAGE
FURNACE
Y/Y2
Second or Full
Stage Compressor
ID MODELS
External Humidistat
(Optional)
Open on Humidity Rise
Thermostat Installer Setup
Step 1 of Thermostat
Installer/Configuration
Menu must be set to “HP2”
0190-Change over Valve
must be set to 0
3 Heat/2 Heat Pump
Two Stage Heat Pump - Two Stage Furnace (Hot Heat Pump or Conventional)
*DP22U70124
*DN22H00124
PT(8/9)
(F/L)*(8/9)T
(G/L)*(8/9)T
TM9*
FURNACE
W / W1
First Stage Heat
W2
Second Stage Heat
RC
AUX
Auxiliary Heat
E/W1
First Stage Aux. Heat
24VAC Humidifier Relay
(Optional)
L
Malfunction Light
L
Malfunction Light
O/B
Reversing Valve
O
Reversing Valve
Energized in Cool
E
Emergency Heat
Thermostat Installer Setup
0170-System Type
must be set to 12
3 Heat/2 Heat Pump
Selection of GAS/ELEC
switch on thermostat
not necessary
Thermostat Installer Setup
0200-Backup Heat Source
must be set to 1
Heat Pump Backup Heat
Source is Fossil Fuel
Thermostat Installer Setup
0210-External Fossil Fuel
Kit must be set to 1
Heat Pump Control
is Controlling Heat Pump
Backup Heat
Change F Fuel jumper
on the heat pump control
to “ON”
Change Hot Heat Pump
jumper on the heat pump
control to “ON” IF Hot Heat
Pump Operation is desired
Single Stage
Compressor
W1 OUT
First Stage Heat
W2 OUT
Second Stage Heat
Y2 OUT
Second Stage
Compressor
Bonnet Sensor
(Optional)
BS
Bonnet Sensor
BSG
Bonnet Sensor
W
Auxiliary Heat
X/L
Malfunction Light
O
Reversing Valve
Energized in Cool
OD MODELLS
YZH
H*5
H*8
YZE
YORKGUARD VI
CONTROL