3. INITIAL 

LIGHTING

 

If turning on the boiler for the first time carry out the following 
steps:

 

 

Check that the electrical supply to the boiler is ON at the  

 external 

isolator.

 

 

Ensure all hot taps are closed.

 

 

Set any remote controls as required.

 

 

Turn the CH control P1 to the minimum setting. Switch    

 

on the appliance at the on/off switch on the control panel. The  

 

boiler will then be in the STANDBY mode.

 

Only operate the boiler when you are sure that the system has 
been correctly filled and vented. If you are in any doubt about the 
boiler being filled with water contact your installer.

4.  OPERATION OF THE BOILER

 

In order to turn on the central heating and adjust the temperature, 
turn the control knob P1 to the desired setting between off and 
maximum 82°C.

 

If the boiler is not required for an extended period turn the control 
knob P1 fully anti clockwise to the off position. In this position the 
frost protection will still be active.

5. RESET 

FUNCTION

 

Should a fault occur, tuRning the central heating water 
temperature control knob P1 to RESET will clear the error and 
enable the boiler to relight. If the fault recurs, turn off the boiler 
and consult a CORGI registered installer.

6. ERROR 

CODES

 

Detailed on page 3 are error codes that you may encounter on 
your boiler. For any sequences not illustrated, please refer to 
your Installation & Maintenance Instructions or contact your local 
CORGI registered installer.

7. FLAME 

LOSS

 

Should the flame signal be lost 5 times in any 4 minute period 
the boiler will lockout and an error code will be displayed on the 
series of LED’s as displayed below. Turning the central heating 
water temperature control (P1) to the OFF position and then back 
on again, will clear the error and enable the boiler to relight

 

If the fault recurs, turn off the boiler and consult a CORGI 
registered installer.

5

Telephone: 01604 762881

Summary of Contents for Reno HE16H

Page 1: ...savingtrust org uk The Johnson Starley Reno range has an energy rating A on a scale of A to G For more information see www boilers org uk This is a certification mark www johnsonandstarley co uk USERS...

Page 2: ...nstructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and...

Page 3: ...he User Panel 4 3 Initial Lighting 5 4 Operation of Boiler 5 5 Reset Function 5 6 Error Codes 5 7 Flame Loss 5 8 Boiler Overheating 6 9 Condensate Drain 6 10 Servicing Maintenance 6 11 Escape of Gas 6...

Page 4: ...ppliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instr...

Page 5: ...nob P1 fully anti clockwise to the off position In this position the frost protection will still be active 5 RESET FUNCTION Should a fault occur tuRning the central heating water temperature control k...

Page 6: ...full maintenance check be carried out annually on the appliance It is also recommended to take out a further service agreement on the expiry of the guarantee period You can obtain further information...

Page 7: ...13 NOTES 7 Telephone 01604 762881...

Page 8: ...Building Regulations HOME COMFORT SOLUTIONS Company Details Website Address www johnsonandstarley co uk Email sales johnsonandstarley co uk marketing johnsonandstarley co uk Telephone Number 01604 76...

Reviews: