background image

2

FOR SERVICE ASSISTANCE, CALL 800-433-0708 OR VISIT JOHNDOW.COM

CONTENTS

GETTING STARTED

CAPACITY AND DIMENSIONS

Item No. Description

Qty.

1

3/4” Hose Clamp

1

2

1” Hose Clamp

1

3

3/4” ID x 8’ Hose w/J-Hook

1

4

25mm ID x 1.8m Hose

1

5

Foot Pump, 25 x 19mm Hose Barbs

1

Product Specification 

JDI-FP1

Flow Rate:  

4.4 gpm (16.7 L/min)

Before assembly, ensure you have all parts according to the contents list. If any parts are missing or damaged, 

contact us for replacement.

DANGER

WARNING

CAUTION

NOTICE

DANGER

WARNING

CAUTION

NOTICE

Indicates a hazardous situation that, if not avoided, could 

result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could 

result in death or serious injury.

• Do not overfill - maximum capacity is 17 gallons.

• Do not use for flammable liquids.

• Wear proper personal protection equipment and clothing.

• Keep the drain port clear of grease and dirt.

• Monitor the fluid level when filling the drain to prevent overflow or spillage.

• Use care when rolling the oil drain when it is full to prevent splashing or spillage.

• Periodically inspect the screen for debris that may prevent the flow of oil.

Important Safety Information

Read this manual and safety information before using this pump. The following 

safety information relates to the use of the JDI-17PLP Low-profile oil drain.

4

2

5

1

3

OPERATION

1. Hook the drain hose to a used fluid container.

2. Connect the 25mm hose to the JDI-17PLP low-profile oil drain to evacuate.

3. Press on the foot pump until the drain is empty.

ASSEMBLY INSTRUCTIONS

1. Attach 25mm hose [4] to inlet side of the pump [5] using 1” hose clamp [2] and 

flat head screwdriver (Figure 1).

2. Attach drain hose [3] to outlet side of pump using 3/4” hose clamp [1] and flat 

head screwdrivers (Figure 2).

Flat head screwdriver

TOOLS & SUPPLIES NEEDED

Figure 1

Figure 2