Care and cleaning

Note

: Switch off and unplug the cooker hood before carrying out any 

cleaning or maintenance work.

Clean the interior and exterior casing using a cloth with water and mild 

(neutral) detergent.

Do not use abrasive cleaning materials or scouring pads when cleaning the 

cooker hood as this may damage the stainless steel finish.

Cleaning and replacing baffle filters

This cooker hood is supplied with baffle filters.

Baffle filters are designed to absorb grease and dust during cooking. They 

should be removed and cleaned once every two months, or more often if 

you regularly fry food.

If all the indicators (see page 6) light up when the cooker hood is switched 

off, this indicates that the baffle filters require cleaning. Once the filters have 

been cleaned, with the cooker hood switched off hold down the 10 Minute 

Timer button until the indicator lights go out.

To clean the baffle filter:

1. 

Remove the baffle filter (A) by turning the handle towards the rear of 

the cooker hood and pulling the filter downwards.

2. 

Wash the filter in warm soapy water or in a dishwasher.

3. 

Replace the baffle filter in the cooker hood by pushing the filter into the 

cooker hood and turning the handle forwards until it locks in position.

The filters may discolour after a few washes. This is normal and does not 

mean that they have to be replaced.

Cleaning and replacing charcoal filters
Note

: This cooker hood is not supplied with charcoal filters. Charcoal filters 

can be obtained from www.johnlewis.com. The model numbers are:

 

– for JLCHI5201, model number JLCHF01

 

– for JLCHI8501, model number JLCHF02

Charcoal filters are designed to absorb grease, dust and unwanted odours 

during cooking. They are only required when the cooker hood is used for 

recirculating (i.e. when it is not ducted out).

If all the indicators (see page 6) light up when the cooker hood is switched 

off, this indicates that the charcoal filters require cleaning. Once the filters 

have been replaced, with the cooker hood switched off hold down the 10 

Minute Timer button until the indicator lights go out.

Non-regenerable charcoal filters must be replaced at least every six months.

To replace the charcoal filters:

1. 

Remove the baffle filter (A) by turning the handle towards the rear of 

the cooker hood and pulling the filter downwards.

2. 

Pull the tab (B) to release the charcoal filter and remove it.

3. 

Insert the new charcoal filter and push it firmly into position.

A

B

Summary of Contents for JLCHI5201

Page 1: ...Instruction Manual JLCHI5201 JLCHI8501 52cm 85cm Cooker hood...

Page 2: ...Care and cleaning 7 Cleaning and replacing baffle filters 7 Cleaning and replacing charcoal filters 8 Cleaning and replacing the oil tank 9 Installation 9 Installing the cooker hood 10 Clearing the s...

Page 3: ...nd the following Cooker hood User guide It is most important this instruction leaflet be retained with the product for future reference These warnings have been provided in the interest of safety You...

Page 4: ...t be in accordance with the Gas Safety Codes of Practice the Gas Safety Installation Use Regulations the Building Regulations issued by the Department of the Environment and where applicable the Build...

Page 5: ...oker hood is operating Replacement filters should be bought from authorised dealers Do not use abrasive cleaning materials or scouring pads when cleaning the cooker hood Electrical information Warning...

Page 6: ...n Speed 2 If the cooker hood is on press this button to set the fan speed to 2 Fan Speed 3 If the cooker hood is on press this button to set the fan speed to 3 Fan Speed 4 If the cooker hood is on pre...

Page 7: ...3 Replace the baffle filter in the cooker hood by pushing the filter into the cooker hood and turning the handle forwards until it locks in position The filters may discolour after a few washes This...

Page 8: ...to release the charcoal filter and remove it 3 Hold the oil tank in position with one hand while loosening the three screws C 4 Slide the tank downwards taking care not to spill the oil 5 Dispose of...

Page 9: ...ter as the air exhaust outlet hole If a two part air exhaust tube is used the upper part must be placed oustide the lower part If installing this cooker hood between adjoining wall cabinets the wall c...

Page 10: ...he exhaust pipe exhaust extraction 8 Connect a pipe to the vent on top of the cooker hood 9 Connect the other end of the pipe to the air exhaust hole 10 Connect the cooker hood to the mains Rear vente...

Page 11: ...is to contact us on 0330 100 3637 You will be given details for your local service engineer When you contact your local service engineer you will need to give the following details Your name address a...

Page 12: ...he cooker hood and wait until it has cooled down The cooker hood is too close to the hob Re site the cooker hood at the correct height No electric current is reaching the cooker hood Check that the po...

Page 13: ...ducted 571 m3 h recirculated 743 m3 h deducted 625 m3 h recirculated Number of Speeds 4 4 Maximum Noise Level 71 db 71 db Rated Input Voltage 220 240V 50 Hz 220 240V 50 Hz Motor Power 281 5W 285 5W En...

Page 14: ...14 John Lewis Partnership 171 Victoria Street London SW1E 5NN johnlewis com Please retain these instructions for future reference...

Reviews: