Cooker hood user guide
10
Preparation for installation
Note:
Before installing the cooker hood, make sure that the
surface it is to be
fi
xed to is strong enough to hold it.
The cooker hood must be mounted so that the minimum
distance between the
fi
lters and the gas or electric hob are
65cm for electric hobs and 75cm for gas hobs. Please ensure
you check with your hob instruction manual before installing.
For most ef
fi
cient operation, we recommend that the cooker
hood is installed 200 - 210cm from the
fl
oor.
The ducting system for this cooker hood must not be
connected to an existing ventilation system which is being used
for any other purpose.
We recommend an air exhaust tube which is the same
diameter as the air exhaust outlet hole. If a two-part air
exhaust tube is used, the upper part must be placed outside
the lower part.
Before beginning installation, remove the
fi
lters (see page 8).
This will make the unit easier to handle during installation.
The cooker hood must be
fi
tted by a quali
fi
ed electrician or
competent person according to the relevant regulations.
Measurements in mm.
Installing the cooker hood
The cooker hood is provided with all the necessary fastenings,
suitable for most surfaces.
The cooker hood can be installed with the motor fastened
directly to either the:
• ceiling (if the distance between the ceiling and false ceiling is
between 247 and 318mm)
• false ceiling (if the distance between the ceiling and false
ceiling is more than 318mm)
The motor can also be fastened up to 7m away from the
cooker hood. If this is done, the cooker hood can only be used
in exhausting mode and the air outlet must not be mounted
on the side. of the exhaust
fi
tting
when it is mounted vertically.
Fastening the motor to the ceiling
1 Measure the distance between the hood and the ceiling
(A).
2 Adjust the separators to the required height (B).
Note:
Minimum height = 164mm; maximum height = 235mm.
Installation
A
390
790
35
840
480
–1140
510
870
247
–1170