Electrical connections
The oven is designed to be connected to
230-240V~(50Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
Caution!
This oven must be earthed!
The cable used to connect the oven to the
electrical supply must comply to the
specifications given below.
For UK use only
Connection via
Min. size Cable/flex
Cable/flex type
Fuse
Cooker Control Circuit 2,5 mm²
PVC/PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current regulations.
The switch must not break the yellow and
green earth cable at any point.
Important!
After installation and
connecting, the cable must be placed so that
it cannot at any point reach a temperature of
more than 50°C above the ambient
temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply
is properly earthed.
The manufacturer declines any
responsibility should these safety
measures not be carried out.
31