5
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Requirements
Electrical Requirements
Electrical Requirements
Electrical Requirements
Electrical Requirements
Any permanent electrical installation must comply with the
latest I.E.E. Regulations and local Electricity Board regulations.
For your own safety this should be undertaken by a qualified
electrician, e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC).
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block which is
marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS O
THIS O
THIS O
THIS O
THIS OVEN MUST BE EAR
VEN MUST BE EAR
VEN MUST BE EAR
VEN MUST BE EAR
VEN MUST BE EARTHED
THED
THED
THED
THED
The cable used to connect the oven to the electrical supply
must comply to the specifications given below.
It is necessary that you install a double pole switch between
the oven and the electricity supply (mains), with a minimum
gap of 3mm between the switch contacts and of a type
suitable for the required load in compliance with the current
rules.
The switch must not break the yellow and green earth cable
at any point.
I m p o r t a n t
I m p o r t a n t
I m p o r t a n t
I m p o r t a n t
I m p o r t a n t
After installation and connecting, the cable must be placed
so that it cannot at any point reach a temperature of more
than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and
the domestic installation can support the load; and that the
power supply is properly earthed.
The manufacturer disclaims any responsibility should these
safety measures not be carried out.
For Uk use only
For Uk use only
For Uk use only
For Uk use only
For Uk use only
FFFFFor Eur
or Eur
or Eur
or Eur
or Europe use onl
ope use onl
ope use onl
ope use onl
ope use onlyyyyy
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Min. size Cable/flex
Cable / flex type
Cable / flex type
Cable / flex type
Cable / flex type
Cable / flex type
Fuse
Fuse
Fuse
Fuse
Fuse
1.5 mm
2
H07 RN-F, H05 RN-F,
13 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
T
T
T
T
Technical Data
echnical Data
echnical Data
echnical Data
echnical Data
Dimensions of recess
Dimensions of recess
Dimensions of recess
Dimensions of recess
Dimensions of recess
Height
in-column: 580 mm
undertop: 593 mm
Width
560 mm
Depth
550 mm
Dimensions of the o
Dimensions of the o
Dimensions of the o
Dimensions of the o
Dimensions of the ovvvvven ca
en ca
en ca
en ca
en cavity
vity
vity
vity
vity
Height
335 mm
Width
395 mm
Depth
400 mm
Oven capacity
53 litres
Installation
Installation
Installation
Installation
Installation
Heating elements rating
Heating elements rating
Heating elements rating
Heating elements rating
Heating elements rating
Conventional Oven (Top Bottom element) 1,800 W
Top element
800 W
Bottom element
1,000 W
Fan Oven
2,000 W
Inner Grill element
1,650 W
Full Grill element
2,450 W
Pizza Oven
2,000 W/1,000 W
Thermal Grilling
1,675 W
Convection Fan
25 W
Oven Light
25 W
Cooling Fan
25 W
Total Rating
2,500 W
Supply voltage (50 Hz)
230 V
Connection
Connection
Connection
Connection
Connection
Min. size
Min. size
Min. size
Min. size
Min. size
Cable / flex
Cable / flex
Cable / flex
Cable / flex
Cable / flex Fuse
Fuse
Fuse
Fuse
Fuse
v i a
v i a
v i a
v i a
v i a
Cable/flex
Cable/flex
Cable/flex
Cable/flex
Cable/flex type
type
type
type
type
• 13 A socket
2.5 mm
2
3 core
13 A min.
outlet
butyl insulated
• 13 A
spur box
• Oven
2.5 mm
2
PVC/PVC
15 A min.
Control
twin and
20 A max.
Circuit
earth