The water heater is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instructions concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the heater.
The wall in which the electrical water heater is installed must be able to bear the load more than
two times of the heater filled fully with water without distortion and cracks. Otherwise, other
strengthening measures must be adopted.
The supply socket must be earthed reliably. The installation height of the supply socket must not
be lower than 1.8m. The rated current of the socket must not be lower than 16A. The socket and
plug must be kept dry to prevent electrical leakage. If the flexible power supply cord is damaged, the
special supply cord provided by the manufacturer must be selected, and replaced by the professional
maintenance personnel.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this
is necessary for the correct operation of the appliance.
When using the heater for the first time (or the first use after maintenance), the heater can not be
switched on until it has been filled fully with water. When filling the water, at least one of the outlet
valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after
the heater has been filled fully with water.
The pressure relief valve attached with the heater must be installed at the cold water inlet of this
heater, and make sure it is not exposed in the foggy. The water may be outflowed from pressure
relief valve, so the outflow pipe must open wide in the air. In order to drain away the water inside
the inner container, it can be drained away from the pressure release valve. Twist the thread screw
of the pressure release valve off, and lift the drain handle upwards(See Fig.1) . The drainage pipe
connected to the pressure release hole must be kept sloping downwards and in a frost-free
environment. The water may drip from the discharge pipe of the pressure-relief device and that this
pipe must be left open to the atmosphere.
During heating, there may be drops of water dripping from the pressure release hole of the
pressure relief valve, this is a normal phenomenon. The pressure release hole shall not be blocked
under no circumstances, otherwise, the heater may get damaged, even resulting in accidents. If
there is a large amount of water leak, please contact customer care center for repair.
The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not
be blocked.
Since the water temperature inside the heater can reach up to 75
℃
, the hot water must not be
exposed to human bodies when it is initially used. Adjust the water temperature to a suitable
temperature to avoid scalding.
If any parts and components of this electrical water heater are damaged please contact customer
care center for repair.
Before installing this water heater,check and confirm that the earthing on the supply socket is
reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use
extension boards. Incorrect installation and use of this electrical water heater may result in serious
injuries and loss of property.
Special Cautions
1. CAUTIONS
2
Summary of Contents for JT100L400178
Page 2: ...1 1 8 9 ...
Page 6: ...5 ...
Page 8: ...7 NOTA ...
Page 9: ...8 ...
Page 16: ...El producto está sujeto a cambios sin previo aviso Conserve este manual ...
Page 32: ...O produto encontra se sujeito a alterações sem aviso prévio Guarde cuidadosamente este manual ...
Page 48: ...The product is subject to change without notice Please keep this manual properly ...