TROUBLESHOOTING
PROBLEM
• There is no spark when lighting
the gas
CORRECTIVE ACTION
• Check that the unit is plugged in and the electrical
supply is switched on
• Check that the RCCB has not tripped (if fitted)
• Check the mains fuse has not blown
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
• The gas ring burns unevenly
• Check the main jet is not blocked and the burner
crown is clear of food particles.
• Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
INSTRUCTIONS FOR THE INSTALLER
Overall dimensions
Width: 600mm
Depth: 510mm
Cut out dimensions
Width: 560mm
Depth: 480mm
TECHNICAL DATA
Burner configuration
LPG I
3+
(28~30/37)
NG (20)
Injector Dia.
(mm)
kW
Injector
Dia. (mm)
kW
Triple Flame (Wok)
0.94
3.5
1.31
3.5
Semi rapid burner (Medium)
0.65
1.75
0.97
1.75
Semi rapid burner (Medium)
0.65
1.75
0.97
1.75
Auxiliary burner (Small)
0.51
1.0
0.76
1.0