8
.
“Double 8 “ Display
This indicator shows 3 functions as below:
1. When the power is on, it shows indoor humidity
2. When you adjust humidity, it shows the selected humidity data
3.
When set the timer on/off, it shows the timer data
Control Panel:
1.
Power button
Press this button to turn on the machine, the machine starts to work in ordinary mode. (Humidity setting is
50%RH and fan speed is high speed as default). The compressor will start to work after the fan has worked
for 2 seconds, the indicate light will show blue and the ionizer will start to work as default.
Press this button again, the machine stops working. The display shows the current humidity and the
machine will be in ready mode. The fan will turn off after 10 seconds and the power indicate and fan speed
indicate light will turn off.
2. Timer button
Press this button to set timing to turn on / turn off for 0~24 hours, press one time to plus one hour and the
display shows the hours you had set. if you would like to cancel timer setting, press this button to 00 shown
from display.
3. Humidity increase setting button
Press this button to adjust humidity as following (The initial humidity is 60%), you can plus the humidity as
you want, and it will show as below: 60%-65%-70%-75%-80%.
When the indoor humidity is lower than the set humidity, the machine would stop automatically.
4. Humidity increase setting button
Press this button to adjust humidity as following (The initial humidity is 60%), you can minus the humidity
as you want ,and it will show as below: 20%-25%-30%-35%-40%-45%-50%-55%-60%.
When the indoor humidity is lower than the set humidity, the machine would stop aautomatically.
-34-