TROUBLE SHOOTING
Breakdown
Case
Removal method
The indicator is not on.
The compressor doses not start.
The plug isn’t connected to
the
socket really.
Replug it.
no power
Connect the socket with power.
The indicator is on ,but the com-
pressor doesn’t work and buzzes
only
The power voltage is
<
187V.
Put a power-regulater more than
1000W power together.
The compressor stops a minute
after start, and restart after a few
minutes, and so repeatedly.
The power voltage is
>
242V.
The compressor works normally,
but the temperature in the cabinet
lowers too slowly.
The doors are opened too
frequently.
Reduce open times.
The food in the cabinet is too
much, and placed improperly.
Place foods properly keep place
between them for ventilation of cold
air.
The frost film is too thick.
Take out foods and defrost.
The surface of the condenser
is too dirty.
Stop and clean the condenser.
The door seals badly.
Adjust the door seal.
The noise is too loud
The freezer is placed
unstably.
Place it stably.
The fixing of the freezer is
loose.
Tighten the fixing.
there’s contact between
pipes.
Separate them.
THE FOLLOWING ARE NOT FAULTS:
When the freezer is working or after is stops for a while, the refrigerant in the pipes is cycling
and gives out
"
running water
"
sounds.
The surface temperature of the compressor may be up 70ºC~80ºC when it is working.
The back side of step freezer gives out heat.
In rainy season, the outer surface of the cabinet may have dew, which makes no defects on
normal use. Just dry it with a piece of cloth.