Jocel JCA002112 Instruction Manual Download Page 23

23 

 

OPERATION INSTRUCTION 

1. 

Pull the unit outwards from the carton and place it on a solid hot-proof horizontal surface. 

2. 

Check if the accessories are complete, same as the accessories list. 

3. 

Add water, water level must be between the MIN and MAX line. 

4. 

Only use the unit with correct AC outlet. 

5. 

Insert the plug pin into a wall socket and turn on the product. 

FUNCTIONS 

1. Principle of Cooling: Water is taking from the water tank by pump to the top, then the water 

drops into paper evaporator. When the water in paper evaporator evaporates to water vapor, 
the air is cooled. People will feel cool wind when the cool air is delivered by fan. 

2. Electronics control: safe and durable, have an attractive appearance. 
3. Adjustable speed and fan type: have three speeds and fan types, and it can send wind from 

side to side neatly. 

4. Cooling: Through air evaporating, cut down the air temperature and raise relative humidity. 
5. Deliver wind at wide angle: swing the blades automatically, deliver wind at wide angle. Also 

swing the blades transversely by your hands, choose the wind direction up and down. 

 

FOR YOUR OWN SAFETY 

1.  Use as per the rating voltage. 
2.  Do not repair or remake the appliance by yourself, it should be repaired by the repairmen. 
3.  Do not operate the appliance with wet hands, in order to avoid damage. 
4.  If the supply cord is damaged, it must be replaced by a special cord or assembly available 

from the manufacturer or its service agents. 

5.  When the appliance is not in use, switch it off and unplug it.  
6.  Do not insert things to air outlets and inlets, in order to avoid damage. 
7.  Do not use the appliance near explosive and combustible gas. 
8.  Use the appliance only on a flat surface. 
9.  Do not use outdoors. 
10. 

The level of water tank should not over “MAX” scale at any time, when humidifying, the 
total level of water tank should not below 

“MIN” scale. 

11. After adding water to the water tank, do not tilt or knock over the appliance when you put 

or move it. If you want to move, please drive it at side, in order to avoid spilling the water. 

12. Do not turnover the appliance. If it is toppled over, and there have some water in the body, 

should unplug the power supply. Then send it to repair department or after-sales service 
and overhaul. 

13. Do not put things on the appliance, do not cover air vent. (WARNING: Do not cover heater, 

in order to avoid over heat.) 

14. Clean  the  appearance  with  a  lightly  damp  cloth.  Do  not  use  any  type  of  detergents  or 

solutions. Do not rinse with water. 

15. Do not make air outlets and inlets near the wall or curtain. 
16. Do not knock or shake the body when use, otherwise it may cause stop. 
17. The water in water tank can easily metamorphose and have odor at summer, renew the 

water frequently. 

18. The appliance must not be located immediately below a socket outlet.  The rating current 

of socket should exceed 10A. 

19. Do not use the appliance in the immediate surroundings of a bath, a shower or a swimming 

pool. 

 
 

Summary of Contents for JCA002112

Page 1: ...CLIMATIZADOR DE AR CLIMATIZADOR DE AIRE AIR COOLER JCA002112 MANUAL DE INSTRU ES MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL...

Page 2: ...consulta futura DADOS T CNICOS PRINCIPAIS Nome do Modelo JCA002112 Tens o Nominal 220 240V Pot ncia Nominal 180W Frequ ncia Nominal 50 Hz Volume de Ar M ximo 4000 m3 h Dep sito de gua 30L Consumo de g...

Page 3: ...ar o aparelho por toque apresentando se como um aparelho de classe superior Sistema de controlo por computador de alto n vel Defini o do temporizador de 1 a 15 horas Nota Devido ao desenvolvimento con...

Page 4: ...AN A 1 Utilize de acordo com a tens o nominal 2 N o repare nem modifique o aparelho voc pr prio este deve ser reparado pela Assist ncia T cnica 3 N o utilize o aparelho com as m os molhadas para evita...

Page 5: ...pela sua seguran a 21 As crian as devem ser vigiadas para assegurar que n o brincam com o aparelho 22 Para evitar o perigo causado pela instabilidade do aparelho tem de o fixar firmemente de acordo co...

Page 6: ...e forma sempre que pressiona a tecla LOW m nimo MEDIUM m dio HIGH m ximo LOW m nimo MODO pressione esta tecla para escolher pode escolher a circula o de ar normal natural e noturna TEMPORIZADOR ao pre...

Page 7: ...a rede do filtro de ar 1 Limpar a rede do filtro de ar Desligue o fornecimento de energia puxe a pega da rede do filtro de ar e retire o do aparelho Limpe a rede do filtro de ar com detergente neutro...

Page 8: ...sist ncia T cnica nas seguintes situa es 1 Funcionamento anormal ou n o funciona depois de efetuar os procedimentos acima 2 Funcionamento anormal causado pela entrada de gua ou coisas estranhas Este s...

Page 9: ...os de acordo com as instru es ou ligados a REDES DE ALIMENTA O que n o garantem uma tens o constante de 220 240V 6 A Garantia n o abrange indemniza es por danos pessoais ou materiais causados direta o...

Page 10: ...ado abaixo Aparelho CLIMATIZADOR DE AR Marca JOCEL Modelo JCA002112 Est em conformidade com as seguintes diretivas europeias e normas de aplica o Baixa Tens o 2014 35 EU EN 60335 1 2012 A11 2014 AC 20...

Page 11: ...ES Nombre del modelo JCA002112 Tensi n nominal 220 240V Potencia nominal 180W Frecuencia nominal 50 Hz Volumen de aire m x 4000 m3 h Dep sito de agua 30L Consumo de agua 3 4 L h Ruido 65 dB Dimensione...

Page 12: ...funci n permite controlar el aparato de manera t ctil Sistema de control inform tico tecnol gicamente avanzado Ajuste del temporizador de 1 a 15 horas Nota Debido al desarrollo permanente del que son...

Page 13: ...de aire ascendente o descendente coloque manualmente los deflectores verticales en la direcci n que desee PRECAUCIONES DE SEGURIDAD 1 Aseg rese de que la tensi n de la red el ctrica corresponda a la t...

Page 14: ...o piscinas 20 Este aparato no debe ser utilizado por personas incluyendo ni os que presenten una disminuci n de sus capacidades f sicas sensoriales o mentales o que carezcan de la experiencia y los c...

Page 15: ...ra cancelar esta funci n pulse de nuevo el interruptor ENFRIAMIENTO Coloque el interruptor de palanca situado en el panel lateral de la unidad en la posici n ENFRIAMIENTO VELOCIDAD Este bot n se utili...

Page 16: ...enci n c No mezcle pilas nuevas y viejas d Cuando no vaya a utilizar el mando a distancia durante un per odo de tiempo prolongado retire las pilas de l AJUSTAR LOS DEFLECTORES BASCULANTES HORIZONTALES...

Page 17: ...de la red el ctrica Retire la pantalla del filtro de aire y retire la almohadilla de agua Limpie la almohadilla de agua con un detergente neutro y un cepillo suave y enju guela a continuaci n con agu...

Page 18: ...en las siguientes situaciones 1 El aparato funciona de manera an mala o no funciona y los procedimientos indicados en la tabla de arriba no permiten solucionar el problema 2 Funcionamiento an malo cau...

Page 19: ...aratos que no est n a ser utilizados de acuerdo a las instrucciones o conectadas a las REDES DE AEREAS DE ALIMENTACI N que no garantizan una tensi n constante de 220 240V 6 La garant a no cubre lesion...

Page 20: ...abajo Aparato CLIMATIZADOR DE AIRE Marca JOCEL Modelo JCA002112 Cumple con las siguientes directivas europeas y normas de aplicaci n Baja Voltaje 2014 35 EU EN 60335 1 2012 A11 2014 AC 2014 EN 60335...

Page 21: ...al for future reference MAIN TECHNICAL PARAMETERS Model Name JCA002112 Rated Voltage 220 240V Rated Power 180W Rated Frequency 50Hz Max Air Volume 4000m3 h Water Tank 30L Water consumption 3 4L h Nois...

Page 22: ...product by touch it looks high class High grade computer control system 1 to 15 hours timer setting Note Due to constant development of our products in regards to specification and design we take res...

Page 23: ...special cord or assembly available from the manufacturer or its service agents 5 When the appliance is not in use switch it off and unplug it 6 Do not insert things to air outlets and inlets in order...

Page 24: ...after the water has been added roll gently to the required position and activate the bracket the castors 25 The power cord is with Y type connection and it must be changed by Qualified Technician if n...

Page 25: ...tion changes as follows when you press the key serially LOW MEDIUM HIGH LOW TYPE Press this key you can choose the normal wind natural wind and sleeping wind circularly TIMER press this key the timer...

Page 26: ...tched off from the supply mains before removing the air filter screen 1 Clean the air filter screen Cut off the power supply pull the handle of air filter screen remove it from appliance Clean the air...

Page 27: ...ance under the situation as follows 3 Abnormal action or no action it is invalid by the above approach 4 Abnormal action caused by ingress of water or foreign things This marking indicates that this p...

Page 28: ...used according to the instructions or connected to FEEDING NETWORKS not guarantee a constant voltage of 220 240V 6 The warranty does not cover damages for personal injury or damage caused directly or...

Page 29: ...ow Voltage 2014 35 EU EN 60335 1 2012 A11 2014 AC 2014 EN 60335 2 80 2003 A1 2004 A2 2009 EN 60335 2 98 2003 A1 2005 A2 2008 EN 62233 2008 Electromagnetic Compatibility 2014 30 EU EN 55014 1 2006 A1 2...

Reviews: