Step
Function
0
pause, no heat required
1
pre-ventilation
2
ignition
3
burner ignited (heating system mode)
4
burner ignited (hot water mode)
5
air pressure switch control
6
burner off (water temp. more than 5
°
C warmer than setting)
7
post-circulation pump in heating mode
8
post-circulation pump in hot water mode
9
burner off because of fault (see shutdown code)
During boiler operation the first figure on the digital display indicates the sequence step while the second gives
the temperature of the water in the boiler.
E.g.
means that the unit is heating at a delivery temperature of around 80
°
C.