- 9 -
(
1
)
Confirm that the battery meets the inverter specifications ensure that the DC
circuit breaker is disconnected.
(
2
)
Unscrew the battery nut, put the cable passes through the nut hole, a sealed
ring, an insulating ring, end out from the nut.
(
3
)
Insert the wire into the battery terminal and press it with the tool.
(
4
)
Remove the combined screw, flat and nut inside the fittings, connect the terminal
to the corresponding position in the inverter, and tighten it with the wrench.
(
5
)
Lock the battery nut by pan head screw inside accessories package, and
then tighten the nut, as shown in figure 4.2-1
Figure 4.2-1
4.3 PV connection
Verify that the DC switch is in shutdown state before PV array connection
.
Note that the polarity of the array must match the polarity of the connector,
otherwise it will damage the inverter.
Note that the maximum open circuit voltage of the array must be less than the
maximum input voltage of the inverter.
PV array’s plus & minus poles are forbidden to ground (PE), otherwise it will
cause damage to the inverter.
Be sure to use the MC4 adapter.
The specific steps of the PV connection are shown in figure 4.3-1 below