Page 1: ...I Solar Pumping Inverter 用户手册 User Manual JNP1K1L G JNP1K5L G JNP2K2L G JNP2K2L G V3 EN V3 0 ...

Page 2: ... document involves the proprietary and confidential information about Solar pumping inverter of Our company It strictly prohibited to disclose the document by duplicating photocopying publishing online and in other forms without Our permission ...

Page 3: ...nverter in details Target Reader This manual applies to the professional engineering and technical person who is responsible for installing and operating of inverter and LCD panel Use the Manual Please read this manual carefully before installing and operating inverter Please keep this manual well for operation and maintenance in future The manual content would be constantly updated and revised bu...

Page 4: ...safety warning is ignored Notice Means that it may lead to moderate accident of injuries equipment moderate damage or part of the business interruption if safety warning is ignored Note Means that the content is additional information Inverter related symbols Symbol Meaning DC power DC AC power AC Protective grounding Refer to relevant instructions Can not discard inverter together with domestic g...

Page 5: ...sconnected then inverter only can be touched Beware of hot surface The inverter temperature can exceed 60 during operation Please don t touch the surface to avoid scald CE certification marks It means that inverter complies with the requirement of CE certification ...

Page 6: ... 2 1 SOLAR PUMPING SYSTEM INTRODUCTION 6 2 2 PRODUCT S INTRODUCTION 8 2 2 1 Appearance 8 2 2 2 Production Dimensions 9 2 2 3 Product Name 9 3 INVERTER UNPACKING 10 3 1 UNPACKING CHECK 10 3 2 IDENTIFY INVERTER 11 4 INSTALLATION PROCEDURE 13 4 1 PREPARE INSTALLATION TOOLS 13 4 2 INSTALLATION STEPS 13 5 INSTALLATION 15 5 1 INSTALLATION SITE REQUIRED 15 ...

Page 7: ...LEVEL SENSOR CONNECTION 30 6 7 1 Water level sensor interface define 30 6 7 2 Water level sensor connection 31 6 8 COMMUNICATION CONNECTION 34 6 8 1 RS485 Communication 34 6 8 2 GPRS Communication 35 6 9 DISASSEMBLING 36 6 9 1Safety Instruction 36 6 9 2 Disassembling of Connector 36 6 9 3 Mounting and dismounting of cover panel 38 7 COMMISSIONING 40 7 1 VERIFY BEFORE COMMISSIONING 40 7 2 INVERTER ...

Page 8: ...METER QUERY AND SETTING 50 8 3 1 Query information item description 50 8 3 2 Setting information item description 56 8 3 3 Information Check 62 8 3 4 Parameter Setting 64 8 4 MALFUNCTION INSTRUCTION 66 9 MALFUNCTION AND TROUBLESHOOTING 68 9 1 TROUBLESHOOTING 68 9 2 MAINTENANCE 72 9 3 CONTACT CUSTOMER SERVICE 73 10 APPENDIX A 74 11 APPENDIX B 76 11 1 QUALITY ASSURANCE 76 11 2 CONTACT US 77 ...

Page 9: ...tallation and operation of JNPxL G series Solar pumping inverter must be completed by professional and technical person Professional and technical person need Receive special training Read this manual completely and master the operation related to safety matters Any damage caused by improper installation or operation which do not according to the introduction in this manual will be beyond the warr...

Page 10: ...l connections Danger Ensure that the solar cell array should be covered by light tight materials before electrical connecting otherwise the solar cell array would produce high voltage under the sun to cause casualties Warning All the operation and wiring work should be operated by professional electrical or mechanical engineer Please do not close switch on breakers before all the equipments are no...

Page 11: ...y be caused non recoverable damage It would influence the machine features and may cause machine damage if the installation environment is selected improperly Do not install the inverter in inflammable explosive place or inflammable explosive materials storage Don t install the inverter in explosive dangerous place Don t install the inverter in place where vulnerable to lightning strike Don t inst...

Page 12: ...sulation Running Danger AC connection should not be turned off directly when AC side of inverter with loads DC connect need to be turned off firstly and ensure that it has really no voltage then DC connection should be turned off Please don t plug any connectors under inverter charged state Please don t open the cover plate under inverter charged state Notice Only LCD display screen and DC switche...

Page 13: ...at AC side breakers should be turned off firstly then DC side breakers should be turned off before checking and maintaining after waiting at least 5 minutes should measure DC side and AC side voltage with a voltage meter to ensure that operation under the circumstance of no voltage between DC side and AC side ...

Page 14: ...ed matching energy required to energy available This enables the system to operate under varying solar isolation levels and provide water throughout the day and through different seasons The PV Pump Inverter utilizes a high efficiency MPPT algorithm to maximize power harvested from PV module JNPxL G series solar pump Inverter add AC IN terminal which support utility AC input work as energy complem...

Page 15: ...Solar pumping application system list No Name Description A PV array Monocrystalline silicon Polycrystalline silicon B Solar pumping inverter JNP1K1L G JNP1K5L G JNP2K2L G C AC pump Three phase AC pump D Water storage device Can be the reservoir fields etc ...

Page 16: ...en also can set some function and parameters of inverter 2 Connection terminals Including DC input terminal PV1 PV1 PV2 PV2 output terminal MOTOR sensor connection terminal SERSOR 3 Nameplate Inverter basic parameters listed on the nameplate for basic information about inverter 4 Machine serial No Machine factory number when need after sales service should provide the number 5 Hanger Help machine ...

Page 17: ...e2 3 Dimension drawing of Solar pumping inverter unit mm Table2 3 Inverter dimension table Model Width mm Height mm Depth mm Net weight kg JNP1K1L G 350 278 197 9 5 JNP1K5L G 350 278 197 9 5 JNP2K2L G 350 278 197 9 5 2 2 3 Product Name The way of product naming take JNP2K2L G for example ...

Page 18: ...od condition After unpacking please check whether the equipment is in good condition According to the packing list to check whether all the parts is correct and in good condition If any damage is found please contact Our company or the transportation company Please keep well the photos taken at the damaged parts and we ll provide you the best and fastest services Our company supply the standard in...

Page 19: ...ol 10 Quick Installation Guideline 4 Expansion bolt 11 Water level sensor Optional 5 PV connector 12 Certificate of inspection 6 AC connector 13 AC IN connector 7 Sensor and communication connector Optional 3 2 Identify Inverter The nameplate in the side of inverter and it shows the inverter model some important parameter and certificate mark Figure3 2 Inverter nameplate ...

Page 20: ...cription 1 Logo and name 2 Inverter model and parameter information 3 Certificate and safety signs concrete meaning as Preface 4 Company and address 5 Inverter factory number Note Photos are for reference only please adhere to the original products ...

Page 21: ...e Table4 1 Installation tools list Sketch map Name Recommend specification Function Wire crimpers M2 5 M8 Used for PV connector wire core pressure welding Electric drill Ф8 Used for inverter installation plate fixed hole drilling Straight screwdriver Ф3 Used for the AC wire installation Cross screwdriver Ф5 Used for disassembling inverter cover 4 2 Installation Steps Tools ready follow these steps...

Page 22: ...d spare parts are Complete 4 1 Whether the installation environment meets the requirements 1 2 Read the manual especially the Safety Instructions 1 3 Choose the best installation location 5 1 Installation 5 3 4 Electrical connection 6 Select cables 6 3 AC side wire connection 6 4 DC side wire connection 6 5 AC IN side wire connection 6 6 Sensor wire connection 6 7 Communication wire connection 6 8...

Page 23: ...nstallation site must be in good ventilation do not install the inverter in the closed case otherwise the inverter will not work properly Inverter protection level is IP65 can be installed outdoor when the inverter is installed outdoor should be installed as far as possible in the eaves or other have the shadow place avoiding direct sunlight rain and snow Inverter is installed indoor keep away fro...

Page 24: ...e5 1 Installation directions The installation height of inverter should be convenient for operation and reading out of the LCD displayed information Do not install the inverter in a place where children can touch The inverter uses air cooling mode and the installation site selected should ensure the minimum installation spacing between the inverter and the fixed object and the nearby inverters to ...

Page 25: ... Front 100cm 5 3 Installation of Inverter Note Fix the inverter on the rock or panel with the toggle bolt or screw is not permitted Our company would provide the bolt which suitable for the installation on the concrete wall If the inverter is fixed on the wooden wall please choose suitable bolt to finish the installation the bolt length should be enough and penetrate the 1 2 depth of the walls ...

Page 26: ...tion according to the size and shape of installation bracket Step2 Fix installation bracket in the located holes with bolts Step3 Tighten the bolts make the bolts cling to the wall Step4 Hang firmly inverter onto the installation bracket then lock the hole ...

Page 27: ...ified electrical personnel can perform the wiring installation work Incorrect wiring operation may cause operating casualties or equipment damage permanently Ensure that there is no electricity in DC side before the electrical connection Grounding correctly using proper conductor and taking necessary Short circuit protection to ensure the safe operation of inverter Don t try to switch on any break...

Page 28: ...nals MOTOR Output terminal connect with AC pump SENSOR Water level sensor signal input terminal COM RS485 or GPRS communication interface Ground terminal 6 2 Schematic Diagram of Electrical Connection Figure 6 2 is the schematic diagram of electrical connection among PV arrays Solar pumping inverter AC input and three phase AC pump Water level sensor and communication interface shall be connected ...

Page 29: ... Computer used for monitoring system general information and remote control inverter s start and stop remote change system operation mode C Pump Three phase AC pump D Communication module Optional can be purchased from Our company E Water level sensor Optional for dry protection F DC side breaker Use for protecting electrical connection user can configure it according to the max input voltage and ...

Page 30: ...ended parameters of DC circuit breaker JNP1K1L G 440VDC 10A JNP1K5L G 440VDC 15A JNP2K2L G 440VDC 15A 6 3 Cable Selection Please select cable according to the following table Table 6 4 Specification of Cables for Electrical Connection Notice 1 DC circuit breaker must be used at DC side it s prohibited to be replaced by AC circuit breaker 2 The left picture is 2 Pin DC circuit breaker 3 AC circuit ...

Page 31: ...lectrical operation Step1 Wire connection of the connector Please connect the wire of AC connector according to the following steps Operation Instruction Operation Demonstration 1 Unscrew all components Inverter Cable range AWG DC side AC side Motor PV PV L N PE U V W PE JNP1K1L G 14 12 14 12 12 14 12 12 JNP1K5L G 14 12 14 12 12 14 12 12 JNP2K2L G 14 12 14 12 12 14 12 12 ...

Page 32: ...onnector terminal and then fully tighten all screws The phase sequence of each hole is signed around the holes Please note that wire U must be connected to hole 1 wire V to hole 2 wire W to hole 3 and wire PE to hole 4 After fasten wires with terminal combine every component together and screw them tightly Step2 Plug the AC connector into the motor terminal at the bottom of inverter ...

Page 33: ...ay and inverter the PV array should be covered with opaque materials and the DC side circuit breaker should be disconnected otherwise the PV array may generate dangerous voltage cause casualty The Non professionals do not make the connection operation Note The phase sequence between AC pump and inverter must be same otherwise it shall lead to less output or without water Whether Phase sequence is ...

Page 34: ...if 2 PV arrays are needed make sure PV arrays are same including the model of PV module number angle azimuth and connecting wires being with the same cross sectional area Inspect every system carefully before installation Step1 Please connect the wire of DC connector according to the following steps Operation Instruction Operation Demonstration 1 Unscrew the nut from connector ...

Page 35: ...nnectors match the core is not reversed 3 Plug cable with tube through the fastening nut 4 Plug the tube into the wiring trough until a sound indicating inserted in place is heard Tighten the nut in a direction opposite Effect picture Step2 Ensure that the DC side circuit breaker is off Step 3 Ensure polarity of PV array is right ...

Page 36: ...use terminals should be covered by taps Warning Make sure the plus minus poles connection of PV array and Inverter are correct 6 6 AC Input connection Danger When carrying out the connection between AC input and inverter AC side circuit breaker must be disconnected otherwise the AC input may generate dangerous voltage and cause casualty Non professionals do not make the operation ...

Page 37: ...ish N L But please pay attn to PE connection AC IN terminal of inverter Diagram 6 5 AC IN wiring diagram Figure6 5 AC IN interface define Terminal AC IN Detail Pin 1 L of AC Black cable Pin 2 The PE of AC Yellow and green cable Pin 3 N of AC Black cable Note 1 AC input voltage range 190 260VAC 2 AC input frequency 50Hz 60Hz ...

Page 38: ...rs location is designed according to your system situation Water level sensor can be bound in corresponding position on the pipeline connected to the pump Other method also can be used to ensure the water level sensor is in the right position The installation of water level sensor must be reliable and effective When use water level sensor to achieve function of overflow protection set OF F as On p...

Page 39: ...ow protection common pin Connected green cable 6 7 2 Water level sensor connection Two kinds of water level sensor you can select are shown below Sensor A Sensor B Figure6 6 Water level sensor Note If you select overflow protection water level sensor you need to set the value of OF F the LCD menu Settings Para Set OF F to modify to ON The setting method with reference to 8 3 4 3 Key Parameters of ...

Page 40: ...ion method is shown below B1 connect white cable B2 connect green cable A2 connect green cable A1 connect black cable Water level sensor connector Note Both yellow shrub like hammer you need filled water when you install sensor A Figure6 7 the detail figure of Sensor A ...

Page 41: ...cable connect white cable Water level sensor connector A the Installation location of overflow water level sensor 1 B the Installation location of pump dryed water level sensor 2 C Pump outlet 3 S about 1 3 m For dry protection the end with cable of sensor should be upwards For over flow protection the end with cable of sensor should be downwards Figure6 9 the installation figure of Sensor B ...

Page 42: ...downwards 6 8 Communication Connection 6 8 1 RS485 Communication RWP or UTP can be used in the connection between inverter and monitoring equipment The COM terminal outside is for remote communication please refer to table 6 5 cross communicating wire through water proof terminal to connect with A B Amphenol connectors inside the machine The following diagram guides you to connect a single inverte...

Page 43: ... converter s correct terminal Please refer to Inverter Management System User Manual for the corresponding monitoring software settings after completing the wire connection Note The monitoring software is optional when choose this function Inverter Management System User Manual can be found from the accompanying CD The inverter is supplied with default address 10 6 8 2 GPRS Communication Note More...

Page 44: ...e Electrostatic discharging will cause damage to the inner components of inverter We should carry out the antistatic measure before disassembling and assembling 6 9 2 Disassembling of Connector 1 The Disassembling of PV Connector PV connector of inverter is not limited to one type if the connected PV connector needed to be removed according to the connection manner of connector to operate The prof...

Page 45: ...r totally as shown on the picture the connectors are disengaged Step 2 Remove the connector 2 The Disassembling of motor connector and AC IN side connecter No professional tools required Just unscrew the connector as shown on the picture Please operate as following Operation instructions Demonstration picture Step 1 Unscrew the nut as shown on the picture ...

Page 46: ...nut as shown on the picture Step2 Remove the connector 6 9 3 Mounting and dismounting of cover panel For any special reason you may need to disassemble the cover and ensure better seal performance please operate according to the following instruction 1 When disassemble inverter cover use the cross screwdriver screw the cover screw in turn and then disengage the grounding wire from the grounding sc...

Page 47: ...over first connect the grounding wire to the grounding screw of the cover Then put cover on use the cross screwdriver the torque is 1 8 0 2N M lock the cover screw in turn Figure6 11 Reference picture of Mounting and dismounting ...

Page 48: ...y AC Input Make sure that the L and N of utility power network are correctly connected to inverter AC Output Make sure that the AC side of inverter is connected correctly and phases of AC side are connected correctly Verify of the water pump motor parameters Check the electrical parameters on water pump motor nameplate the rated input voltage and input current frequency to ensure inverter is match...

Page 49: ...modify the Imotor value equal to 1 2 times of the motor rated current the details please refer to chapter 8 3 4 3 Key Parameters of the System Set Imotor settings After finishing the above steps machine shall start operation after long time pressing the ON OFF key for 4s check if the solar pumping system works properly or realize suitable head of delivery and flow Press ON OFF and stop the inverte...

Page 50: ...cessful need to set the system shutdown frequency as follows Step 1 Ensure the system is running and there has water output To enter StopFreq interface Please refer to 8 3 4 3 Key Parameters of the System Set Step 2 To reduce the value of StopFreq Reduce 5 each time every change need to press ENTER to confirm Keep reducing till there just has no water output and make a small change to just get sma...

Page 51: ...d on Beijing time zone Please reset time if it doesn t match local time so that the inverter can record daily total generating capacity and historical faults information Please refer to 8 3 4 1 Display Time Set Finished the commissioning of the Solar pumping system ...

Page 52: ...dicator Name Color Instructions POWER Power light Green Light on When power on RUN Running light Green Light on under normal operation FAULT Faulty light Red Light on when error occur off when fault disappear Detail Explanation of Indicator When inverter is powered up POWER indicator green will be lighted Communication fault occurs FAULT indicator flashes rapidly Other outage or shutdown mode occu...

Page 53: ...ress once to stop long time press for 3s to get it started UP Page up and increase data long time press for Continuous increase DOWN Page down and decrease data long time press for Continuous reduction ENTER To choose and confirm DOWN ENTER Return to main interface Note When inverter is powered up LCD display background is lighted and after 30s normal running the background light turns off ...

Page 54: ...id Igrid State_AC Ucap Fout Iaout Ibout Icout Temp ErrCode StopCode S Mode D Mode OF F Run Stop GPRS ESC LCD Ver DSP Ver SiteNum SN Ty Date Time ESC RunT D RunT D E Day E Tot ESC 密码 00 Time T Limit Para Set Pump Para Set SiteNum Set Clear S Date Clear F Date Password Set Language Set ESC Current Fault History Fault ESC ESC Initialize Waiting Run Waiting 5 Pump Info Hpump Qpump npump Pout Vday Vtol...

Page 55: ...47 Figure8 2 LCD diagram 1 ...

Page 56: ...e ESC Para Set Imotor D Power D Time StopFreq F Limit Load D Mode OF F OF Time M Mode V Hys T Delay ESC Pump Para Set H_rate Q_rate N_rate ESC Clear S Date YES NO Clear S Fate YES NO Password Set CodeValue ESC Language Set Lang ESC SiteNum Set NumValue ESC ESC Figure8 3 LCD diagram 2 ...

Page 57: ... after long time pressing ON OFF key Note The default mode of inverter is manual start stop mode When inverter power for the first time it need key press to start the inverter to drive pump Run after long time press ON OFF at the same time manual start stop mode will change into automatic start stop mode directly Press ON OFF stop the inverter and it will get started while long time pressing ON OF...

Page 58: ...er 10s or you can turn page through pressing UP and DOW N button 8 3 System parameter query and setting 8 3 1 Query information item description The query information items include main interface information operation information basic information water pump information statistical information and fault information All query information items can be queried on the LCD display interface Figure 8 2 ...

Page 59: ...face parameters Parameters Instructions Ppv PV input power W R Mode Operation mode MPPT Ipv PV input current A Vdc DC Bus input voltage V Pgrid Grid input power W State_AC State of Grid input Iaout Inverter A phase current A Fout Inverter output current frequency Hz Run Stop Run or stop state Run Inverter running Stop Inverter stop and pump stop work D Mode Dry mode of PV pump system AUTOMATIC doe...

Page 60: ... 6 6 water level sensor connect for detail Table8 4 Information list of main menu Item Explain RunInfo Display running data of inverter InverterInfo Display basic information of inverter Pump Info Display information of Pump Statistic Statistical information of running time data and power Inverted Settings Inverter s parameter setting Fault Inquiry Inquire current and historical fault ESC Return t...

Page 61: ...de The most recently error mode StopCode Stop code can check the reason of inverter shut down most recently S Mode Start and stop mode D Mode Protection mode against well dry out OF F Water overflow alarm function optional in PV pump system storage device Run Stop run stop status GPRS State of 485 connection ESC Return to the previous menu 8 3 1 2 Basic Information Inverter Info shows basic inform...

Page 62: ...figure is modifiable please refer to 8 3 4 1Display Time Set Time Current time modifiable please refer to 8 3 4 Display Time Set ESC Return to the previous menu 8 3 1 3 Pump Information The pump information item displays the basic information of the pump Table 8 5 pump information introduction Pump information description remark Hpump Pump Running head Qpump Pump current flow npump Pump current sp...

Page 63: ...ion of inverter Please refer to figure below Table8 7 Detailed statistic data Statistic Explain Remark RunT D Inverter daily running duration This figure will be reset when recharged RunT T Accumulative running duration Could be reset manually E Day Daily power inverted E Tot Accumulative power inverted can be reset manually Could be reset manually ESC Return to the previous menu 8 3 1 5 Fault inf...

Page 64: ...clearing fault information password setting and language setting Figure 8 2 LCD menu block diagram 1 Figure 8 3 LCD menu block diagram 2 lists the parameter settings and the location of all the information items that can be set under this menu The following describes each item Settings Description Time Adjust LCD display time T Limit To set the stopping time according to user requirement inverter ...

Page 65: ...ble 8 8 Time set Time Explain Year Adjust LCD display year Month Adjust LCD display month Date Adjust LCD display date Hour Adjust LCD display hour Minute Adjust LCD display minute ESC Return to the previous menu 8 3 2 2 Timing Shutdown Time Set T Limit to set timing shutdown time of the inverter which is convenient for the user to set according to the need so that the inverter stops automatically...

Page 66: ...e rated output power of Inverter For example the D Power of 1 1kW pump is 330 D Time Dry out recovery tim auto dry out mode after the warning of dry out and inverter shut down the duration from shut down to restart Default value is 30 Default duration is 30 minutes Detecting dry mode after the warning of dry out and inverter shut down the duration from shut down to restart Default value is 30 Defa...

Page 67: ...ion Over flow recovery time after the warning of over flow and inverter shut down the duration from shut down to restart Default value is 30 Default duration is 30 minutes M Mode If water output is abnormal and caused by reversed motor phase sequence you can try to reset this model from REV to FWD Default is FWD V Hys AC input frequency limit change voltage T Delay AC input frequency limit change ...

Page 68: ... Set for remote RS485 communication use Please refer to the table below Table 8 12 Sitenum set instruction SiteNum Set description remark SiteNum Inverter network station number Maximum 64 8 3 2 6 Statistical Data Clear The cumulative running time and generating capacity of the inverters Table 8 13 Clearing Power Generation Information Description Clear S Data description Remark YES Choose yes cle...

Page 69: ...information explaination No Return to the previous menu 8 3 2 8 Password setting Table 8 15 password set explanation Password Set description remark New password Set the password to enter the Settings menu The default initial passwords is 00 and the maximum value can be set to 99 8 3 2 9 Language setting Language set to set the man machine interface language category Table8 16 language set explana...

Page 70: ...isplayed in the main interface pressing the ENTER could enter the main menu and query the detailed parameters of the inverters and set some parameters The following is illustrated with the query fault code as an example 1 Firstly locate the fault code According to Figure 8 2 LCD Menu Box Figure 1 it can be seen that the fault code is under the operation information menu 2 Running Information is a ...

Page 71: ...the cursor falls on the running information item 3 Press enter to enter the operation information item for query 4 Press up or down to move the cursor and find the fault code Note All items can be queried according to the above operations Here illustrated with the query fault code as an example Refer 8 3 1 Query Information Item Description for an introduction to query information items ...

Page 72: ...meters Settings menu 2 Language Settings is to set information items The specific steps are as follows Operation step and LCD display description Main Menu Password 0 ESC or Settings Fault Inquiry Settings Password ESC RunInfo InverterInfo RunInfo 1 Press enter in the main interface to enter the main menu and the cursor falls on the running information item 2 Press up or down to find parameter set...

Page 73: ...s on time settings 2 Press enter to select the language setting 3 Press enter to start set the LCD display language 4 Press up and down to change language 5 Choose the language that needs to be replaced and press enter to confirm it again after confirmation 6 Choose yes finish setting like the left hand figure shows the LCD language is switched from Chinese to English 7 At the same time press the ...

Page 74: ...rror screen This interface will appear and Fault red led flickers to show malfunction this means internal communication malfunction is appear Fault 2 Fault105 Figure8 21 Fault screen Display show malfunction fault LED lights up shows inverter malfunction or stop Press UP or DOWN to inquire current malfunction choose ESC press ENTER to quit When LCD screen show fault code and fault LED lights up wh...

Page 75: ...on code LCD showed code Name of malfunction and condition Fault100 Driving over current State101 Array voltage low Fault104 Radiator over heating Fault105 Output over load Faul1t06 Array over voltage Fault107 Array over current Fault108 AC over current State109 Dry alarm State110 Weak sunshine Fault111 Temperature sensor fault Fault112 Short circuit fault Fault113 Initialization error from the mac...

Page 76: ...wn when the fault appeared and will automatically restart after it disappear Out put energy from array changes Please check the input voltage from array and make sure this voltage inside inverter input voltage range Note In cloudy days morning or down this situation is not malfunction State109 Inverter shut down until the water level recover or protection recover time is up the machine will restar...

Page 77: ...end level sensor If this situation appears more than once please check onsite and set the water level sensor at a proper height Table9 2 Malfunction and troubleshooting Condition code Phenomena Cause value Troubleshooting Fault100 Inverter shutdown and will restart automatically after the fault disappears Short circuit in output wire Please check if there is short circuit in output wires Fault105 ...

Page 78: ...mum input voltage Fault107 Inverter shutdown and will restart automatically after the fault disappears Input current of inverter higher than rated maximum value If this happen please contact Our company Fault108 Inverter shutdown and will restart automatically after the fault disappears 1 Power capacity of pump motor is higher than rated output 2 Pump motor locked rotor or damaged 3 Pipe system de...

Page 79: ...rter shutdown and will restart automatically after the fault disappears Phase loss in inverter output 1 Please check if the output wires are proper connected and fixed 2 If this happen frequently please contact Our company Fault 200 AC input over voltage Inverter stops and display AC over voltage 1 AC power source is unstable with high voltage 2 Inverter internal damage Fault201 AC input low volta...

Page 80: ...parameters and time settings are correct Every half to one year a routine examination should be done Warning Please check and make sure the inverter is not charged with electricity before any maintain work below Check humidity and dust of inverter surrounding environment if have too much dust clean the inverter Check the inverter cable connection is loose if loose tightening again according to the...

Page 81: ...mping inverter please contact us Telephone 86 551 62931312 0323 Email sales jnnewenergy com In order to provide faster and better service please provide us with information below Model of Inverter Series number of inverter Malfunction name and time Malfunction description ...

Page 82: ...Rated AC input 195 260Vac Recommended MPPT voltage range 150 400Vdc Max input DC current 8A 10A 14 6A MPPT efficiency 99 Input number of string 1 1 2 AC output Max applicable motor output power 1 1kW 1 5kW 2 2kW Rated output voltage 220 240Vac 3 phase Output frequency range 0 50 60Hz Rated output 5 5A 7A 11A ...

Page 83: ... 97 97 97 Protective class I Protection level IP65 Operation temperature range 25 to 60 above 60 need rated operating Cooling methods Nature air cooling Display LCD Communication interface RS485 GPRS Altitude 3000m above 3000m need rated operating Noise emission 50dB Standard EN 50178 IEC EN 62109 1 IEC 61800 ...

Page 84: ...ot to assume quality assurance Conditions The replaced products should be returned to Our company Our company should be given reasonable time to repair the malfunctioning equipment Exemption from liability The company has the right not to carry out quality assurance in the following Transport damage Incorrect installation modification and usage Overall components have been beyond the warranty peri...

Page 85: ... the latest information given by the company shall prevail without notice 11 2 Contact Us If you have any question about Solar pumping inverter please contact us and we will be happy to give you answers Please remember the following contact information ...

Page 86: ...78 ...