71
State101
Inverter shutdown
when
the
fault
appeared and will
automatically
restart
after
it
disappear
Out put energy
from
array
changes
Please check the input
voltage from array and make
sure
this
voltage
inside
inverter input voltage range.
Note:
In
cloudy
days,
morning,
or
down,
this
situation is not malfunction.
State109
Inverter shut down
until the water level
recover
or
protection recover
time is up, the
machine will restart
automatically.
Water level of
source is lower
than
low-level
water
level
sensor,
even
lower than inlet of
pump.
1. Please check the water
level, if the water level is ok,
please check if there are air
inside pump.
2. Please check the position
of water level sensor.
State 110
Inverter shutdown.
When malfunction
disappear,
inverter can restart
automatic.
Array output low.
Usually appears in early
morning, dusk and cloudy
days. This situation is aim to
protect the motor of pump
and lengthen the lifetime.
State 114
Inverter shut down
until the water level
recover
or
protection recover
time is up, the
machine will restart
automatically.
Water level in
container higher
than
high-end
level sensor.
If this situation appears more
than once, please check
onsite and set the water level
sensor at a proper height.
Summary of Contents for JNP110KH-V3
Page 22: ...14 Note Photos are for reference only Please adhere to the original products ...
Page 32: ...24 PE Output load grounding terminal ...
Page 42: ...34 and Installation Manual for GPRS ...
Page 53: ...45 8 1 3 LCD Display Interface Overview ...
Page 64: ...56 Figure8 10 Parameter setting Note Default value of factory password is 00 ...