background image

 

 

9

there is a key

C

F/

controlling the on/off of blower

 

BLOWER will auto off when working 2 hour later

 

 

(16)Fahrenheit & Celsiur temperature shift

 

In the status of

U

Power off

U

”,

pressing the key

C

F/

  can change the mode of 

Fahrenheit & Celsiur 

temperature 

 

(17)

 When there is no water in the bathtub

 water pumps

  blower and constant temperature system will not 

start up

 However

  the corresponding signal on the LCD will flash

 

 

(18) Frozen preventing control

 

The heater & circulation pump will on when water temperature is under 5

℃,

And will off when up 10

℃。

The 

function is effective when power on

 

 
 

4.Electric parameters

 

(1) Performance index

 

Rated voltage

 220-240VAC/50Hz

110VAC/60Hz

                      Maximum working current

 60A

100A/110V

 

Voltage-resistance

  1250V/1 minute without penetration

   Isolative resistance 

>=200M

Ω

 

Water resistance grade

 IPX4

                                                    Electric shock resistance

 first grade 

 

(2) Output loading index 

Heater

 AC220V/2KW. 

   

                                                            Water pump

 AC220V/2 H

P×1

     

Air pump

AC220V/700W

×1

       

                         

 Water pump

 AC220V/1.5 H

P×1

 

Spa light

  AC12V/20W                                                                      Ozone

 AC12V/15W  

Radio

  1) Frequency Range

 FM

 87.0~108.0MHz 

                2) Maximum Output Power

 10W 

3) Speaker

8

Ω

damp proof speaker 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for SPA-308

Page 1: ...1 OUTDOOR SPA SPA 308 PROGRAMMING INSTRUCTIONS ...

Page 2: ...wer on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater On Off TEMP Temperature setting Note Function of buttons with blue part...

Page 3: ...leaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in the status of power off or no pressing operation lasting above 30 minute In the status of Locked press the button MEM twice the lock will be unlocked and the word LOCKED will disappear 3 Time setting operation In the status of UPower offU and the pre ...

Page 4: ...of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will start at this moment only MIN and HOUR are available to change the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stop The adjustment range is 0 59 It will add 1 hour when pressing HOUR each time and...

Page 5: ...ONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circulation cleaning must be in Power OFF status 2 Circulation PUMP and OZONE are not working while all setting time 5 Pre heating setting Only one pre heating setting is allowed each day The LCD can show clearly in the following figures about...

Page 6: ... hour when pressing HOUR each time please note that the maximum of continual time is 19 hours and 50 minutes When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to the temperature setting of pre heating It will show SET label on the LCD panel press TEMP and button could change the temperature setting The range of temperature setting is 25 45 5 When eve...

Page 7: ...own time In the circulation cleaning process till cont down time finished the circulation cleaning will be turned off automatically by system or by pressing ON OFF key intentionally 8 Operation to Power ON OFF Pressing the key will enter from UONU to UOFFU or UOFFU to UONU At the same time the LCD will show whether the power is on or off AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Operation to Temperature...

Page 8: ...p 3 are control surf pump3 Pump3 are circulation pump at the same time The LCD will show when circulation and heating Including preheating are tune on In spite of pump3 are on or off PUMP1 PUMP2 will auto off when working 2 hour later 12 Operation to Ozone The ozone could be started up in the status of circulation cleaning Press the key OZONE to turn on off the ozone After the startup of ozone if ...

Page 9: ...ater circulation pump will on when water temperature is under 5 And will off when up 10 The function is effective when power on 4 Electric parameters 1 Performance index Rated voltage 220 240VAC 50Hz 110VAC 60Hz Maximum working current 60A 100A 110V Voltage resistance 1250V 1 minute without penetration Isolative resistance 200MΩ Water resistance grade IPX4 Electric shock resistance first grade 2 O...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...OM ACN ACN P3 P2 NO COM NC NO COM PUMP2 DVD TV HEAT ACN ACN P1 220VAC NC NO COM COM NO NC PUMP3 BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP2 CONNECTION FACE DVD TV ACN ACL HEAT PUMP1 MAIN BOARD ...

Reviews: