background image

 

 

7

ON/OFF

 key intentionally

 

***

 

Notice

 *** 

1

 

When setting temperature is lower or equal water temperature

Even the 

Pre-heating is working but the circulation PUMP and HEATER are not 
working

 

2

 

When the HEATER is 

I

frame

The power of circulation PUMP must 

reach 750W

 

3

 

Answer for condition of 

2

and the HEATER is not working

Please 

short the line of water press switch

 

 

(7)circulation-cleaning: 

When the time of real time and pre-heating time is consistent, meanwhile, there is water in the bathtub and 

the circulation-cleaning button is

on

  the system will start the circulation-cleaning

  and the circulation pump 

and ozone(If it is on) will work at the same time

 Then LCD will show count down time

 In the 

circulation-cleaning process

  till cont down time finished the circulation-cleaning will be turned off automatically 

by system or by pressing   

ON/OFF

 key intentionally

 

 

(8) Operation to Power ON/ OFF 

Pressing the key 

  will enter from 

U

ON

U

 to 

U

OFF

U

 or 

U

OFF

U

 to 

U

ON

U

  At the same time

  the LCD will show 

whether the power is on or off

 

AM

OFF

               

AM

OFF

 

Fig

9

  OFF                                                    Fig

10

 ON 

 

(9) Operation to Temperature setting 

In the status of 

U

Power-on

U

 and 

HEATER

 is working 

The temperature setting can operate

 only 

key 

TEMP

are available

  It will add 

1

℃ when pressing “

TEMP

 and the 

temperature could be 

added continually  till 45

 when pressing the 

TEMP

without stop

At this time 

, when pressing 

TEMP

 angin

and the 

temperature could return 25

 

The range of adjustment is 25~45

 

 

 

(10)Operation Radio & CD: 

AM

PUMP3

 

Fig

11

  Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel)   

Summary of Contents for SPA-302

Page 1: ...1 OUTDOOR SPA SPA 302 PROGRAMMING INSTRUCTIONS ...

Page 2: ...wer on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater On Off TEMP Temperature setting Note Function of buttons with blue part...

Page 3: ...leaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in the status of power off or no pressing operation lasting above 30 minute In the status of Locked press the button MEM twice the lock will be unlocked and the word LOCKED will disappear 3 Time setting operation In the status of UPower offU and the pre ...

Page 4: ...of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will start at this moment only MIN and HOUR are available to change the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stop The adjustment range is 0 59 It will add 1 hour when pressing HOUR each time and...

Page 5: ...ONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circulation cleaning must be in Power OFF status 2 Circulation PUMP and OZONE are not working while all setting time 5 Pre heating setting Only one pre heating setting is allowed each day The LCD can show clearly in the following figures about...

Page 6: ... hour when pressing HOUR each time please note that the maximum of continual time is 19 hours and 50 minutes When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to the temperature setting of pre heating It will show SET label on the LCD panel press TEMP and button could change the temperature setting The range of temperature setting is 25 45 5 When eve...

Page 7: ...own time In the circulation cleaning process till cont down time finished the circulation cleaning will be turned off automatically by system or by pressing ON OFF key intentionally 8 Operation to Power ON OFF Pressing the key will enter from UONU to UOFFU or UOFFU to UONU At the same time the LCD will show whether the power is on or off AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Operation to Temperature...

Page 8: ...p 3 are control surf pump3 Pump3 are circulation pump at the same time The LCD will show when circulation and heating Including preheating are tune on In spite of pump3 are on or off PUMP1 PUMP2 will auto off when working 2 hour later 12 Operation to Ozone The ozone could be started up in the status of circulation cleaning Press the key OZONE to turn on off the ozone After the startup of ozone if ...

Page 9: ...ntrol The heater circulation pump will on when water temperature is under 5 And will off when up 10 The function is effective when power on 4 Electric parameters 1 Performance index Rated voltage 220 240VAC 50Hz 110VAC 60Hz Maximum working current 60A 100A 110V Voltage resistance 1250V 1 minute without penetration Isolative resistance 200MΩ Water resistance grade IPX4 Electric shock resistance fir...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...OM ACN ACN P3 P2 NO COM NC NO COM PUMP2 DVD TV HEAT ACN ACN P1 220VAC NC NO COM COM NO NC PUMP3 BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP2 CONNECTION FACE DVD TV ACN ACL HEAT PUMP1 MAIN BOARD ...

Reviews: