SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3121773
– JLG Lift –
6-5
6.3
SERVICE/MAINTENANCE
Cleaning the Machine
WHEN WASHING THE MACHINE, THE MAIN POWER SWITCH MUST BE DISEN-
GAGED, THE KEY REMOVED AND THE EMERGENCY STOP BUTTON PRESSED.
•
Washing the outside of the machine;
Never use flammable liquids. Adopt the above
safety measures to prevent sparks due to short-cir-
cuits.
If washing the track with a cleaning solution, care-
fully cover all the vital parts and above all the elec-
trical components. Follow the instruc tions
provided by the manufacturer of the cleaning
solution.
Clean the machine using only water-soluble deter-
gents.
The more often the machine is cleaned, the more it
will need to be re-greased
(see lubrication chart)
.
Do not wet the electric motors and the other elec-
trical components directly.
Do not aim the spray directly onto decals and rat-
ing plates.
•
Cleaning the electrical system;
NEVER CLEAN THE INVERTER OR THE ELECTRIC MOTOR WITH WATER, AS
THIS MAY CAUSE DAMAGE TO THE ELECTRICAL SYSTEM.
ONLY USE DRY DETERGENTS, IN ACCORDANCE WITH THE MANUFACTURERS’
INSTRUCTIONS. NEVER REMOVE COVERS, GUARDS AND THE LIKE.
Clean the electrical system using a dry, non-metal-
lic brush and low pressure air.
•
After cleaning
Dry the machine carefully before starting it again
(for example using compressed air).
IF, DESPITE ALL THE PRECAUTIONS, MOISTURE HAS PENETRATED INTO THE
ELECTRIC MOTOR OR OTHER PARTS OF THE ELECTRIC SYSTEM, THESE MUST
BE DRIED USING COMPRESSED AIR TO AVOID THE RISK OF SHORT CIRCUITS.