SECTION 3 - TROUBLESHOOTING AND FAULT CODES
3-4
31215460
Table 3-3. Inverter Fault Codes
Error Code
Error Condition
Error Description
Corrective Action
1
Wrong Config
Eeprom memory not configured. Contact JLG.
8
Watch Dog
The inverter is not able to
activate or turn off the electric
motor.
Control connections and
continuity of the electric motor. If
they are OK replace the inverter.
8
Flash Checksum
Software is corrupted or inverter
is damaged.
Replace the inverter.
13
Eeprom KO
Hardware or Software problem in
Eeprom.
Replace the inverter.
16
Aux output KO
Electromechanical brake
problem.
Usually it is a temporary anomaly
due to a working condition. In
case the anomaly persists replace
the inverter.
17
Logic failure #3
Activates in case of high peak of
current in the inverter.
Usually it is a temporary anomaly
due to a working condition. In
case the anomaly persists replace
the inverter.
18
Logic Failure #2
Fault in the inverter.
Replace the inverter.
19
Logic failure #1
An overvoltage or a sudden
voltage drop occurred.
Usually it is a temporary anomaly
due to a working condition. In
case the anomaly persists replace
the inverter.
26
Current Sens KO
Current sensor for the motor
phases is damaged.
Replace the inverter.
27
Phase KO
One of the motor phases is open. Check the connection from the
inverter to the motor.
28
Pump Vmn Low
Pump motor output is too low.
Check the electric motor
connection.
29
Pump Vmn High
Pump motor output is too high.
Check the electric motor
connections.
30
VMN low
Inverter supply voltage is lower
than the batteries’ one, or the
connection with the positive
terminal of the battery is not
correct.
Control the connection with the
positive terminal of the battery. If
the anomaly persists, replace the
inverter.
31
VMN High
One motor phase is not correctly
connected or is broken.
Control motor phases and motor
internal connections. If the
anomaly persists, replace the
inverter.
37
Contactor closed
The relay remains closed with
power to the coil disconnected.
Control the relay.
38
Contactor Open
The inverter supplies power to
the relay coil, but the contact
does not close.
Control the relay and the power
to the coil.
40
Aux driv Shrt
When the mos of EB is shorted.
Check the battery feed.