SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
2-10
3121170
2.3
OSCILLATING AXLE LOCKOUT TEST (IF EQUIPPED)
The front axles will oscillate when the boom is in the transport posi-
tion.
LOCKOUT SYSTEM TEST MUST BE PERFORMED QUARTERLY, ANY TIME A SYSTEM COM-
PONENT IS REPLACED, OR WHEN IMPROPER SYSTEM OPERATION IS SUSPECTED.
NOTE:
Ensure the axles are extended and the boom is fully retracted,
lowered, and centered between the rear wheels prior to begin-
ning lockout cylinder test.
1.
Place a 6 inches (15.2 cm) high block with ascension ramp in
front of left front wheel.
2.
From platform control station, start engine.
3.
Place the Drive control lever to the forward position and
carefully drive machine up ascension ramp until left front
wheel is on top of block.
4.
Carefully extend the boom just enough to get it out of the
transport position.
5.
With boom in this position, place Drive control lever to
Reverse and carefully drive machine off of block and ramp.
6.
Have an assistant check to see that left front or right rear
wheel remains elevated in position off of the ground.
7.
Carefully return the boom to the transport position. When
boom reaches the transport position, carefully activate Drive
to release cylinders. The lockout cylinders should release
and allow the wheel to rest on ground.
8.
Repeat the procedure for the right oscillation cylinder check-
ing to see that the right front or left rear wheel remains ele-
vated in position off of the ground.
9.
If lockout cylinders do not function properly, have qualified
personnel correct the malfunction prior to any further oper-
ation.
To
order go
to
Discount-Equipment.com