SECTION 8 - DIAGNOSTIC TROUBLE CODES
8-14
– JLG Lift –
3121222
4-4 Battery Supply
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
441
BATTERY VOLTAGE TOO
LOW - SYSTEM SHUT-
DOWN
The power module momen-
tarily measured battery voltage
under 14.5V between ground
board J1-39 and ground board
J1-40.
•
Recharge batteries or check for damaged batteries.
•
Check battery charger function.
442
BATTERY VOLTAGE TOO
HIGH - SYSTEM SHUT-
DOWN
The power module momen-
tarily measured battery voltage
> 37.0V.
•
May be due to improper battery charging or incorrect voltage batteries
being used.
443
LSS BATTERY VOLTAGE
TOO HIGH
The load sensing system mod-
ule momentarily measured bat-
tery voltage > 34.0V.
•
May be due to improper battery charging or incorrect voltage batteries
being used.
•
Refer to Section 2.3: Troubleshooting in the LSS manual, 3124288.
444
LSS BATTERY VOLTAGE
TOO LOW
The load sensing system mod-
ule momentarily measured bat-
tery voltage < 9V.
•
Recharge batteries or check for damaged batteries.
•
Refer to Section 2.3: Troubleshooting in the LSS manual, 3124288.
446
LOGIC SUPPLY VOLTAGE OUT OF
RANGE
The system module logic supply
voltage was measured to be out
of normal operating range by
the interface PCB (<11V).
•
This may be caused by a loose battery terminal, severely discharged bat-
teries, damaged battery, or an improper wire harness connection.
•
Drive, Steer, and Lift Prevented
•
ZAPI - HEALTH (Status LED) - ON
4421
LOGIC SUPPLY VOLTAGE OUT OF
RANGE
The system module logic supply
voltage was measured by the
power PCB to be more than 34V
for 10uS.
•
This may be caused by a loose battery terminal, severely discharged bat-
teries, damaged battery, or an improper wire harness connection.
•
Drive, Steer, and Lift Prevented
•
ZAPI - HEALTH (Status LED) - ON
4422
LOGIC SUPPLY VOLTAGE OUT OF
RANGE
The system module logic supply
voltage was measured by the
power PCB to be less than 11V
for 10uS.
•
This may be caused by a loose battery terminal, severely discharged bat-
teries, damaged battery, or an improper wire harness connection.
•
Drive, Steer, and Lift Prevented
•
ZAPI - HEALTH (Status LED) - ON
6-6 Communication
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
661
CANBUS FAILURE -
POWER MODULE
The control system failed to
receive messages from the
power module.
•
Check for 24V between power module 12 position connector terminal 1
and the power module B- terminal. If this is the problem, the line contac-
tor may be cycling on and off, making a clicking noise when the machine
is powered.
•
Disconnect ground board J1 and power module connector. Ground board
socket J1-31 to power module connector socket 10 should have continu-
ity. Ground board socket J1-32 to power module connector socket 11
should have continuity.
•
Turn on machine in platform mode. If DTC 662 is present, troubleshoot
that DTC before continuing.
Summary of Contents for 1230ES
Page 1: ...AS NZS Service and Maintenance Manual Model s 1230ES P N 3121222 June 22 2017 ...
Page 2: ...NOTES ...
Page 24: ...SECTION 1 MACHINE SPECIFICATIONS 1 12 JLG Lift 3121222 NOTES ...
Page 32: ...SECTION 2 GENERAL SERVICE INFORMATION 2 8 JLG Lift 3121222 NOTES ...
Page 78: ...SECTION 4 BASE COMPONENTS 4 40 JLG Lift 3121222 NOTES ...
Page 104: ...SECTION 5 CONTROL COMPONENTS 5 26 JLG Lift 3121222 NOTES ...
Page 158: ...SECTION 8 DIAGNOSTIC TROUBLE CODES 8 22 JLG Lift 3121222 NOTES ...
Page 198: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 40 JLG Lift 3121222 ...
Page 199: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 3121222 JLG Lift 9 41 ...
Page 200: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 42 JLG Lift 3121222 ...
Page 202: ...SECTION 9 GENERAL ELECTRICAL INFORMATION SCHEMATICS 9 44 JLG Lift 3121222 NOTES ...