
1
JLid-COMM Amplifier Port Connections
The MVi-HUB is equipped with one “Master” and five numbered JLid-COMM ports to connect to the JLid-COMM ports on MV
and MVi amplifiers. All JLid-COMM connections are made using standard CAT5e network cables (not included). For optimum
performance, use only CAT5e type network cables and keep cable lengths as short as possible. Refer to the table below for
connection info. When selecting the “Master” amplifier, keep in mind that the USB port on the “Master” amplifier is the connection
point for the PC or Mac® used to set up and tune the amplifiers in the network, using TüN™ software.
JLid-COMM Ports
on MVi-HUB
Connection
Note
JLid-COMM Master Port
JLid-COMM Port of the Master MVi Amplifier
(required for MVi-HUB operation)
For TüN™ configuration using a PC or Mac®, connect your
computer to the USB Port of the Master MVi amplifier only.
JLid-COMM Ports 1 to 5
JLid-COMM Port of Slave Amplifiers (MV or MVi models)
2
Amp Identifier and Status LEDs
Each JLid-COMM amplifier port is outfitted with a status LED that will illuminate solid blue when connected to an amplifier.
Pressing an Amp Identifier button on the MVi-HUB will change its status LED to white and cause the top LED on the connected
amplifier to flash white. This functionality is useful for identifying specific amplifiers after installation.
3
Control Source and Status LEDs
Press the Control Source button to toggle between optional control methods. Refer to the table below for connection info.
Control Source Selection
Connection
Functionality
JLid-CTRL
VXi-BTC Bluetooth® Communicator
Wireless configuration of an amplifier network,
using a compatible device running TüN® applications
Compatible M-DRC and DRC Controllers
Preset selection and level controls (varies by model)
NMEA 2000®
NMEA 2000® Network
Not used (TBA/future development)
4
NMEA 2000® Connection
Currently not used, this connection is intended for future NMEA® 2000 control options (TBA).
5
JLid-CTRL Port
The JLid-CTRL Port allows the connection of an optional control accessory (sold separately). Refer to the table below for compatible
accessories. For additional information, refer to the documentation included with each accessory.
JLid-CTRL Accessory
Functionality
Note
Digital Remote
Controller
M-DRC-50 Push-button preset selection only. Includes RGB LED ring to identify selected preset.
Only use DRC cable
for this connection
DRC-205
Remote preset selection and adjustment of levels, fader and balance. Includes RGB LED
ring to identify selected preset.
Note: This controller is not marine-rated.
Bluetooth®
Communicator
VXi-BTC
Permits wireless configuration of an amplifier network, using a compatible device
running TüN™ Mobile and TüN™ Express applications.
Note: The VXi-BTC provides a
control interface only and does NOT support audio streaming.
Only use CAT5e cable
for this connection
6
USB Port
The USB Port allows connection of a PC for future firmware updates to the MVi-HUB using a standard USB A/B cable (not included).
Note: For TüN™ configuration using a PC or Mac®, connect your computer to the USB Port of the “Master” MVi amplifier only.
7
Reset Buttons
Use a small pin to perform the following:
(A) Factory Reset (wipe memory, reboot MVi-HUB) - Press and hold Button A for 7 seconds. All user settings will be
erased and the MVi-HUB will revert to its factory settings!
(B) Reboot MVi-HUB - Press and release Button B to restart the MVi-HUB. Previous user settings will be retained.
10.58 in
267 mm
3.98 in
101 mm
11.21 in
285 mm
2.05 in
52 mm
Blue:
Connected
White:
Amplifier ID Request
REQUIRED
2
4
1
3
7
6
5
APPENDIX A: FREQUENTLY ASKED QUESTIONS
“Do I still need to send audio input signals to my amplifiers?”
Yes, audio input signals connections are required for each amplifier.
“Where do I connect my USB A/B cable for TüN™ configuration?”
Compatible computers running TüN™ software should connect to the USB Port of the Master MVi amplifier only.
“Where do I connect my DRC controller?”
Compatible DRC remote controllers should be connected to the JLid-CTRL Port of the MVi-HUB.
“Why isn’t my DRC controller working?”
Make sure JLid-CTRL has been selected using the Control Source button of the MVi-HUB.
What is TüN?
TüN™ is software that you use to configure MV or MVi amplifiers, and other JL Audio DSP products. TüN™ automatically
recognizes what it is connected to, and allows you to make adjustments with a clear interface specifically set up for that
product. TüN™ is available for download for free in a variety of applications, for computers and most handheld devices. For
more information, visit: jlaudio.com/tun
For Windows® PC or Mac® computers, TüN™ connects via USB and offers complete control and command of
the entire MV and MVi feature set from the comfort of your desk or driver’s seat. Software also runs in demo
mode, without connected amplifiers, for offline setup or demo purposes. Test drive it for free!
For iPad or Android tablets. Enjoy the TüN™ software experience on your tablet, with the freedom
of a wireless connection via Bluetooth®. Requires VXi-BTC Bluetooth® Communicator.
Wireless connection and streamlined options, for fast and simple amplifier setup. Download
TüN™ Express
for iPhone, iPad and Android phones & tablets. Requires VXi-BTC Bluetooth® Communicator.
Specifications
Host Interface
Proprietary JLid™ protocol
Input Operating Voltage
5 VDC
IP Rating
IPX2 (when mounted vertically with connections pointed downward)
Dimensions L x W x H
11.21 in x 3.98 in x 2.05 in / 285 mm x 101 mm x 52 mm
Connect to JLid-COMM Port
on each “Slave” MV or MVi
Amplifier (up to five)
Connect to JLid-COMM Port
on “Master” MVi Amplifier
Connect to optional
JLid-CTRL accessory
(sold separately)
Note:
- JLid™ Network Connections are made via CAT5e Network Cables (not included)
- JLid™ Network Connections support data communication only - No Audio
- Power and Audio Input connections (not pictured) are required for each amplifier.
- Components pictured may not be to scale.
For TüN™ configuration using a
PC or Mac®, connect your
computer to the USB Port of the
“Master” MVi amplifier only.