background image

 |  JL Audio - M800/8-24V Owner’s Manual  

TURN-ON LEAD

The M800/8-24V uses a conven12 to 

24V remote turn-on lead, typically controlled by 

the source unit’s remote turn-on output. The 

amplifier will turn on when any voltage between 

+12V and +24V is present at its Remote” input 

and turn off when this voltage is switched off. If a 

source unit does not have a dedicated remote 

turn-on output, the amplifier’s turn-on lead can 

be connected to +12V to +24V via a switch that 

derives power from an ignition-switched circuit. 

Remote

Level

Control

CH. 5

(L)

CH. 6

(R)

CH. 3

(L)

CH. 4

(R)

CH. 1

(L)

CH. 2

(R)

Bridged

CH. 7

(L)

CH. 8

(R)

Bridged

Bridged

Bridged

INPUT SECTION

(L)

(R)

CH. 1&2

CH. 3&4

CH. 5&6

CH. 7&8

+24 VDC

Ground

Remote

NOT FOR USE IN 12V SYSTEMS!

The M800/8-24V’s “Remote” turn-on 

connector is designed to accept 18 AWG –  

12 AWG wire. To connect the remote turn-

on wire to the amplifier, first back out the set 

screw on the top of the terminal block, using 

the supplied 2.5mm hex wrench. Strip 1/2 inch 

(12mm) of wire and insert the bare wire into the 

terminal block, seating it firmly so that no bare 

wire is exposed. While holding the wire in the 

terminal, tighten the set screw firmly, taking 

care not to strip the head of the screw and 

making sure that the wire (not the insulation) is 

firmly gripped by the set screw.

Summary of Contents for M800/8-24V

Page 1: ...the training expertise and installation equipment to ensure optimum performance from this product Should you decide to install the amplifier yourself please take the time to read this manual thoroughl...

Page 2: ...nty This product is not certified or approved for use in aircraft Do not attempt to bridge the outputs of this amplifier with the outputs of a second amplifier including an identical one PLANNING YOUR...

Page 3: ...e 2 Ch 4 Ch 8 Ch CH 7 L CH 8 R CH 7 8 Filter Mode Filter Freq Hz Input Sens Off HP LP CH 5 L CH 6 R CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 CH 5 6 CH 2 R Filter Mode Filter Freq Hz Input Sens Off HP LP Fil...

Page 4: ...ve power wire to the negative battery post Use the same size power wire as the wire connected to the 24V connection minimum 4 AWG 5 Run signal cables and remote turn on wire from the source unit to th...

Page 5: ...ied 2 5 mm hex wrench Strip 1 2 inch 12 mm of insulation from the end of each wire and insert the bare wire into the terminal block seating it firmly so that no bare wire is exposed While holding the...

Page 6: ...ircuit Remote Level Control C CH 1 L CH 2 R Bridged INPUT SECTION L R CH 1 2 CH 3 4 CH 5 6 CH 7 8 24 VDC Ground Remote NOT FOR USE IN 12V SYSTEMS The M800 8 24V s Remote turn on connector is designed...

Page 7: ...election pg 8 Ch 1 2 Input Sensitivity Control pg 7 Ch 3 4 Filter Frequency Selector pg 8 Ch 3 4 Filter Mode Selection pg 8 Ch 3 4 Input Sensitivity Control pg 7 Ch 5 6 Filter Frequency Selector pg 8...

Page 8: ...P Filter Mode Filter Freq Hz Input Sens Off HP LP Filter Mode Filter Freq Hz Input Sens Off HP LP L R 1 Filter Mode Control The M800 8 24V employs a 12dB per octave filter for each pair of channels Ea...

Page 9: ...audio will mute completely At full clockwise rotation the level will be the same as if the HD RLC was not connected at all In other words it operates strictly as a level attenuator Remote Level Mode A...

Page 10: ...t and Right speaker connectors only The Left and Right remain unused When bridged each channel pair will deliver optimum power into a single 4 ohm load When a pair of channels are bridged they will de...

Page 11: ...d and is accompanied by a muting of the affected channel s Because the muting behavior may be very short in duration it may manifest itself as an audible repetitive ticking noise in the output Over cu...

Page 12: ...ry in the JL Audio amplifiers requires specifically trained service personnel Do not attempt to service the amplifier yourself or through unauthorized repair facilities This will not only void the war...

Page 13: ...13...

Page 14: ...nce of the speaker system connected to the amplifier outputs 6 Verify that you have disconnected the speakers before proceeding Play a track with an appropriate sine wave within the frequency range to...

Page 15: ...referred to rated power A weighted 20 Hz 20 kHz noise bandwidth 84 dB referred to 1W A weighted 20 Hz 20 kHz noise bandwidth Frequency Response 12 Hz 22 kHz 0 1dB Damping Factor 150 4 ohms per ch 50...

Page 16: ...ired To test for this problem jump the 24VDC wire to the Remote terminal to see if the amplifier turns on I hear a repetitive ticking or popping sound coming out of the speaker s Check the speaker wir...

Page 17: ...source unit while an appropriate test tone is played through the source unit disconnect the input cables from the amplifier prior to this test The frequency used should be in the range that is to be...

Page 18: ...ter Mode Inpu Sen Off HP LP CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 L R CH 7 CH 8 INPUT SECTION 24 VDC Ground Remote 2 Ch Input 1 feeds CH 1 CH 3 CH 5 CH 7 Input 2 feeds CH 2 CH 4 CH 6 CH 8 4 Ch Input 1 feeds C...

Page 19: ...8 Filter Mode Filter Freq Hz Input Sens Off HP LP CH 5 L CH 6 R CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 CH 5 6 CH 2 R Filter Mode Filter Freq Hz Input Sens Off HP LP Filter Mode Filter Freq Hz Input Sens...

Page 20: ...hereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights wh...