background image

金 科 达 诚 安 检 设 备 有 限 公 司

J K D C S E C U R I T Y C O L I M I T E D

Add: Jinkedacheng Science Park,N0.59 Xinhe Road,Shangmugu,Pinghu Town,

Longgang District,Shenzhen City,GuangDong Province,China

Web: http://www.securityjkdc.com

Tel: +86 755-28408621

3

14. LED direction indicator.

15. Gate autoopens when power off and autoclose when power on, complying

with fire safety requirements.

16. Alarm function, in case of illegal intrusion and reverse intrusion, etc.

17. Counter function (optional).

18. Support infrared photocell for anti-pinch and reset function.

3. Technical Specifications

4. Control Interface

1) Equipment controlling connection method:

For two-way relay and switch signal:

The COM connect to the

VDD

from Gate Opening interface,

The NO signal need to connect to the

OPE-L

(or

OPE-R

).

For The 12V level signal:

The negative electrode connect to the

GND

from Gate Opening interface.

The Positive electrode connect to

OPE-L(or OPE-R)

2) Pair using must connect the synchronous wires correspondingly, e.g.

GND to

GND

,

OPE-L to OPE-L

(6 wires total, the connection must be completely

consistent).

Model

Item

JKDJ-100C

Voltage

AC 220V/110V±10%

Frequency

50/60Hz

Current

3A

Control circuit:

DC24V

Power consumption

40W

Working temperature

-20°C~60°C

Working humidity

0~95%RH

Time of opening or

closing

2.5 seconds

Summary of Contents for JKDC-100C

Page 1: ...J K D C S E C U R I T Y C O L I M I T E D 1 Swing Gate User Manual JKDC 100C...

Page 2: ...nd various consumption devices 2 Features and Functions 1 SUS304 stainless steel rainproof case 2 LINIX the best micro motor brand in China brush less DC motor is used and its surface is plated with d...

Page 3: ...pecifications 4 Control Interface 1 Equipment controlling connection method For two way relay and switch signal The COM connect to the VDD from Gate Opening interface The NO signal need to connect to...

Page 4: ...ina Web http www securityjkdc com Tel 86 755 28408621 4 Note Before using please make sure ground wire connected prohibit taking electricity from the main board Wiring Diagram Menu Setting I Display a...

Page 5: ...et itto 60 the time is 6 seconds If the barrier hasn t closed in 6 sec it will automatically stop System default is 60 P03 The passing time measurement is second Number 10 means 10 seconds If the pede...

Page 6: ...using The covers are made by 10mm thick PVC materials On the standard decorative cover the words Please put in your card here are printed using silk screen printing method The background of the decora...

Page 7: ...f the specific layout environment and power supply conditions propose reasonable design schemes to customers striving for best price value 2 Sales Service A Assemble and adjust the equipment system to...

Page 8: ...ior aftersales service support If any question arises in the operation please call the service support hot line of our company Our engineer will be glad to answer your questions Thanks again for your...

Page 9: ...uch as fire earthquake etc b Any failure arising from improper operation not satisfying requirements or from use under unaccepted working environment and conditions c Any failure arising from the repa...