Piping Methods

Do not install the NBT tanks in a vertical position. 

Only mount in a horizontal position on the floor.

 

Figure 5

  

Piping for Single Heating Unit with Common NBT pH Treatment Tanks and Flue Drain Connection

Figure 6

  

Piping Multiple Heating Units/Single NBT pH Treatment Kit / Common Vent Piping / 

Common Condensate Drain

C

F

B

A

E

Piping for Single Heating Unit with Common NBT-23 pH Treatment Tank and

Flue Drain Connection

Figure 4

Key

A

Rev. 01/2016

Flue Drain/Trapped

B

C

D

E

F

Boilers/Hot Water Heaters/Furnaces Condensate Drains

Single Flue Vent

NBT-23 pH Treatment Tank

House Drain

Boilers, Hot Water Heaters, Furnaces

Note: Contact Factory for PH Treatment Tube and Tank Sizing and Piping Sizing

D

G

Gas/Water Trap

G

G

C

F

F

F

F

B

E

Piping Multiple Heating Units/Single NBT-23 pH Treatment Kit /Common Vent

Piping/Common Condensate Drain

Figure 5

Key

A

Rev. 01/2016

Flue Drain

B

C

D

E

F

Boilers/Hot Water Heaters/Furnaces Condensate Common Drain

Common Flue Vent

NBT-23 pH Treatment Tank

House Drain

Boilers, Hot Water Heaters, Furnaces

Note: Contact Factory for PH Treatment Tank Sizing and Piping Sizing

G

D

G

Condensate Trap

A

G

G

G

G

Boilers / Hot Water Heaters / Furnace Condensate Drains

Flue Drain/Trapped

Single Flue Vent

NBT pH Treatment Tank

House Drain

Boilers / Hot Water Heaters / Furnaces

G    

Gas/Water Trap

Note: 

Contact Factory for pH Treatment Tank and Piping Size

Boilers / Hot Water Heaters / Furnace Condensate      

Common Drain

Flue Drain

Common Flue Vent

NBT pH Treatment Tank

House Drain

Boilers / Hot Water Heaters / Furnaces

G  

Condensate Trap

Note: 

Contact Factory for pH Treatment Tank and Piping Size

NBT

series Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance

6

Summary of Contents for NBT Series

Page 1: ...ion Maintenance Models NBT 610 NBT 230 14 Coleman Ave Westfield MA 01085 413 527 1893 690 Island Way Unit 206 Clearwater FL 33767 413 427 3373 jjmboilerworks com Revised August 2018 Acidic Waste Water...

Page 2: ...sedbythefollowing A Improper Combustion B Contaminated Combustion Air C High Sulfur Content in Gas Supply D pH below 2 0 is considered hazardous waste by EPA Contact JJM Technical Service at 413 427 3...

Page 3: ...BT 230 outlet level falls below 5 0 At a minimum the media bags must be changed once a year Use only JJM pH Power Pellet media bags DO NOTE USE LIMESTONE OR MARBLE CHIPS What is pH The pH measurement...

Page 4: ...ing Operational Flow 1 Once the heating unit is fired and acidic condensate is produced the condensate will flow from the heater condensate drain down into the NBT tank s inlet port The acidic condens...

Page 5: ...Boiler Works Inc 4 3 4 A B C D 7 8 3 5 INLET 7 8 From Base to Center 4D Outlet 3 1 2 Base to Center A E 6 50 E 1 NBT 610 pH Treatment Tank Part No 2010 NBT 23 pH Treatment Tank Ratings Dimensions in i...

Page 6: ...nt Tank Single Unit Condensate Pump igure 3 Key A Rev 01 2016 NBT 23 pH Treatment Tank B C D E F Boilers Hot Water Heaters Furnaces Condensate Drains Trap Flue Pipe Trap Floor Drain Note Contact Facto...

Page 7: ...d Piping Sizing D G Gas Water Trap G G C F F F F B E Piping Multiple Heating Units Single NBT 23 pH Treatment Kit Common Vent Piping Common Condensate Drain Figure 5 Key A Flue Drain B C D E Boilers H...

Page 8: ...nd install electric heat tape provide and install electric heat tape and insula tion on the condensate drain lines and around the NBT tanks to prevent possibility of neutralizer tube damage or line bl...

Page 9: ...rs dur ing re charging for cleaning of the tank bottom This should be done by a trained technician Contact your local wholesaler or manu facturer s representative for replacement parts Dealerlistingat...

Page 10: ...your neutralizer pellets are incased in a porous pellet bag there are three methods to agitating the pellets 1 Remove the pellet bag or bags from the tank and using your hands move the pellets around...