Sheet 2 NEXT - GPN

 231080 Rev.A

Sheet 2 NEXT - GPN

 231080 Rev.A

6 inch Flue Kit (Eureka & Jindara)

Spigot

3rd Skin

2nd Skin

1st Skin

Heater

10” Upstand

• 10” Upstands

55mm

97mm

• 8” Upstand

10” Gal Flue

8” Gal Flue

6˝ S/S Flue

8” Upstand

425mm

370mm

10”

8”

450mm

370mm

4th Skin

 

 

Non-combustible

hearth

Breast plate no

thicker than 30mm

 (appliance to

mantle upright)

 (max)

2

 

p

e

t

S

1

 

p

e

t

S

Plaster, timber, MDF etc.

Minimum 4mm thick 

cement sheet, villaboard

or non-combustible

material on front face

of framing

Minimum Requirements:

 5 x 6” S/S Flue

 4 x 8” Gal Flue

 4 x 10” Gal Flue

Note: Some states will use different size flue kits

which will require the appropriate upstand. 

Non-combustible material can 

overlap clearance gap between 

ZCB and frameing, and run over 

the front of the ZCB. DO NOT 

silicon or adhear material to ZCB

as heat expansion of ZCB will 

cause cracking.

H

G

J

I

E

Vent - Position vent 

such  that access  is 

available to fan power 

supply when vent is 

removed. 

NOTE: Position of upstands on Zero Box di ers depending

on model type. Line up centre screw hole on Zero Box with

corresponding notch on upstands.

Barossa, Stockade

& Kimberley Models

Opal & Riverina

        Models

   Hamersley Models

        Victorian Insert 

  & Federation Models

Hearth depth

mm in front 

of unit 

Vent may be 

located in the

wall of on the floor. 

Compact Zero Clearance 

Cabinet Installation 