background image

MMAINTENANCE  AND INSTRUCTION MANUAL - 3

English

TABLE OF CONTENTS

1.

SAFETY INSTRUCTIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

03

2.

MAIN COMPONENTS

.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

04

3.

INTRODUCTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

05

4

GENERAL DESCRIPTION

.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

05

4.1. Operation.

5.

SYSTEM SETUP

.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

06

5.1. Installation recommendations.
5.2. Power supply connection.
5.3. Starting up.

6.

INDICATIONS FOR END USERS

.  . . . . . . . . . . . . . . . . . . . . .

08

7.

MAINTENANCE OPERATIONS

.  . . . . . . . . . . . . . . . . . . . . . . . .

09

7.1. Cleaning.
7.2. Troubleshooting guide.
7.3. Motor disassembly and extraction.
7.4. Replacement/cleaning of non-return valve.

8.

TECHNICAL SPECIFICATIONS

.  . . . . . . . . . . . . . . . . . . . . . . . .

12

9.

LAYOUT AND SECONDARY VENTILATION 
SYSTEM DIAGRAM

.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

10. EXPLODED VIEWS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

10.1. Lifting station assembly.
10.2. Caset assembly.

11. BASIC INFORMATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

12. EC DECLARATION OF CONFORMITY

. . . . . . . . . . . . . . .

16

.

1. SAFETY INSTRUCTIONS

In order to reduce the risk of
electric shock, do not open the
top covers. Do not handle the
interior of the macerator; always
refer servicing to qualified
personnel.

In order to reduce the risk of fire
or electric shock, do not expose
this appliance to rain or flooding. 

DETAILED SAFETY INSTRUCTIONS.

Please read all the safety and operating
instructions before using the appliance. Keep
them for future reference.

All the user safety indications, instructions and
operations included in this manual must be
observed.

LIFTING STATION 

EB-705

MMAINTENANCE 
AND INSTRUCTION
MANUAL

1

en

English

Summary of Contents for CICLON LS EB-705

Page 1: ...EXPLODED VIEWS 14 10 1 Lifting station assembly 10 2 Caset assembly 11 BASIC INFORMATION 15 12 EC DECLARATION OF CONFORMITY 16 1 SAFETY INSTRUCTIONS In order to reduce the risk of electric shock do no...

Page 2: ...th a wet cloth and mild soap Do not use solvent or acidic cleaning prod ucts Unplug this apparatus when unused for long periods of time and make sure the stopcock for any sani tary fixture connected t...

Page 3: ...det shower bathtub sink urinal washing machine dishwasher Each sanitary fixture can be connected to the lifting station through the 40 mm inlet with the conical joint and the nut supplied The total fl...

Page 4: ...provide enough of a height difference towards the drainage inlets The use of non siphoned outflows is recom mended for the installation of shower basins or bathtubs see connection recommendations on p...

Page 5: ...nnection with the down pipe by means of a 45 bypass If the joint with the downpipe is below the base of the lifting station a ventilation valve Jimten A 69 type must be connected at the highest point...

Page 6: ...t will not begin working until a minimum level of water is reached in the tank and a residual level of water will always remain inside the unit 6 INDICATIONS FOR END USERS Once the lifting station is...

Page 7: ...f removing limescale deposits it is recommended that a cleaning be carried out periodically following these steps Disconnect the lifting station from the electrical network Pour a mixture of 1 litre o...

Page 8: ...ical Assistance The motor does not work with the water of one of the sanitary fixtures connected The auxiliary connections are obstruc ted or the non return valve is blocked Lack of aeration or gradie...

Page 9: ...be hot Replace the caset assembly with the spare and assemble it again following the steps in reverse order see electrical connections page 9 screw in and replace the caset cover The whole process can...

Page 10: ...Inlets Top 2 1 x 40 mm inlets for 40 32 mm smooth pipes Lower side 2 1 x 40 mm inlets for 40 32 mm smooth pipes with non return valve Upper side 1 1 x 40 mm inlet for 40 32 mm smooth pipes with non r...

Page 11: ...MAINTENANCE AND INSTRUCTION MANUAL 13 LIFTING STATION EB 705 English A CONNECTION TO EXISTING VENTILATION PIPE B 32 DISCHARGE PIPE WITH 1 GRADIENT C DRAINAGE INLET PIPE 1 GRADIENT 32 or 40 MM D ACCORD...

Page 12: ...TION FLOAT 7B AERATION FLOAT JOINT 8A TANK ENCLOSURE COVER 8B BODY GASKET 9A ACTIVE CARBON DEPOSIT 9B ACTIVE CARBON DEPOSIT COVER 10 DEPOSIT COVER 11 CASET COVER 12 CIRCULAR COVER 13 CIRCULAR COVER FI...

Page 13: ...ES 1 DEPOSIT BODY 2 CASET GASKET 3 CAPACITOR 4 THREE WIRE HOSE 5 BUSHING JOINT 6 MOTOR 7 MOTOR INSULATION DISK 8 PRESSURE SWITCH 9 PRESSURE SWITCH PIPE 10 22 X 3 O RING 11 MOTOR SCREW CAPS 12 MOTOR FI...

Page 14: ...RUNGEN Elektromagnetische vertr glichkeit 89 336 EWG AB NDERUNGEN Est conforme aux directives Directive Basse Tension 73 23 CEE amendements Directive Compatibilit lectromagn tique 89 336 EEC amendemen...

Reviews: