Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
PURE (EN) June 2018
8
USER NOTICE
Starting a fire
Before lighting, remove ashes especially on the stainless steel canals.
Do not exceed the maximum loading authorized.
IMPORTANT actions before starting your fire:
1
For the correct use of the appliance, the door must be opened slightly for 15 minutes -
the time necessary to reach a sufficient temperature in the fireplace.
2
When the window is hot, please close the door. Combustion air inlet is regulated by the
automatic thermostat to obtain reduced wood consumption with respect to the heat
recovered. When the fireplace is hot, fans start automatically. For devices with manual
thermostat, you have to reduce the air inlet according to the wished heat.
CAUTION
-
For good performance do not remove completely the ashes of the stove.
-
When the fire needs a reloading, set the speed controller on minimum. Open slightly
the door in order to avoid reverse flow of smokes in the room. After loading, do not
forget to position ventilation on the desired position.
-
If you have a device with ventilation, never make it work without ventilation!
In case of momentary power failure, reduce the load and keep a medium heat.
Devices without ventilation MUST be decompressed in opening the two hot air outlet
and fixing 2 ducts of at least 1 meter (on the right and left side of the fireplace).
-
The fireplace is designed to a door-closed use, after starting the fire. Reload when only
glowing embers remain.
-
We advise you to use fire starter cube which facilitate a quicker and cleaner wood
combustion.
-
Do not use inflammable liquid products.