Fitting of the combustion air intake 
 
You may face two specific cases: 
 
1

 

No possibility or necessity of an external combustion air inlet: 
Remove the air box front side, which allows to take combustion air  in the room and 
leave also the back air inlet open.  

 
 

PURE   

 

 

 

 

 

 

PURE 77 XL 

 
 
 
 
 
 
 
 
 
 
 

 
2

 

Plug  the  external  air  inlet  to  the  back  of  the  short  stainless  steel  or  to  the  bottom 
(remove the plate and fill the back inlet). In this case, keep the air box face. 

 
 
 
 
 
 
 
  
 
 
 
 
 

 

Summary of Contents for PURE 58/47

Page 1: ...AINTENANCE PURE Full automatic PURE Manual Congratulations You have chosen an appliance of the Jid range and we would like to thank you for it We are convinced that it will bring you warmth and comfor...

Page 2: ...eparation Arrangements 11 Fitting 13 Fitting of the finishing frame option 13 Fitting of the chimney connection 14 Fitting of the connection for the convection air option 14 Fitting of the combustion...

Page 3: ...be modified as it could present a real danger and will invalidate the warranty A list of our dealers installers is available on our site www jide be en Before using your fireplace for the first time...

Page 4: ...The primary air arrives under the grate and the stainless steel canals to foster fire lighting in the fireplace The preheated secondary air creates post combustion by reburning the gases and this gre...

Page 5: ...uel wood PURE 70 70 Nominal power 9 5 kW Nominal efficiency 79 4 CO emissions 0 09 Fuel wood PURE 77 51 Nominal power 9 4 kW Nominal efficiency 79 4 CO emissions 0 09 Fuel wood PURE 77 XL Nominal powe...

Page 6: ...the information contained on a plaque that accompanies this notice stating in particular the power efficiency and CO emissions of the appliance This plaque must be kept and will enable your appliance...

Page 7: ...te the working speed of your fireplace after started Thanks to the temperature sensor on the right side of the device the thermostat automatically settle the coming of air by opening of closing the ai...

Page 8: ...draft will not enable a high enough temperature to be reached for good combustion Too small a draft will lead to a risk of reverse flow fouling of the window and sooting of the chimney An approved chi...

Page 9: ...ironment Damp smoke has disadvantages for example a reduced draft and the formation of tar in the flue and on cold surfaces the window for example Split wood presents better combustion and will improv...

Page 10: ...ter will obviously not be covered by the warranty Deformation of the baffle Bleaching of the glass Degradation of the vermiculite Accentuated noise of the ventilator Deterioration of the automatic the...

Page 11: ...of smoke to the chimney being able to reach 300 to 400 this one could cause a combustion of not isolated combustible materials Provide high temperature insulation around the fireplace to protect cert...

Page 12: ...flue is much more important than the one of the stove it is advised to tube the chimney on all its height and to insure the sealing of connection It is necessary to be vigilant on the state of the ex...

Page 13: ...replace must be aligned with respects to the plane of the masonry to enable the correct attachment of the frame A three and a four sided frame are available as options The finishing frame clips onto t...

Page 14: ...led for the chimney connection It fits onto the appliance When the duct is placed on the appliance fold back the 2 safety clamps Fitting of the connection for the convection air option Your appliance...

Page 15: ...e two specific cases 1 No possibility or necessity of an external combustion air inlet Remove the air box front side which allows to take combustion air in the room and leave also the back air inlet o...

Page 16: ...ion Your appliance is equipped with fans controlled by a speed controller This is the diagram for their electrical connection Attention disconnect the power before working on the electrical 1 Speed co...

Page 17: ...tom vermiculite 4 Remove the back vermiculite 5 Unscrew and remove the back plates Ventilation access Integrated ventilation and airstat access for Pure 67 51 77 51 77XL 58 47 70 70 16 9 Unscrew and r...

Page 18: ...rmostat access Automatic thermostat access for Pure 67 51 77 51 58 47 70 70 16 9 Full automatic Unscrew and remove Remove the 2 M6 nuts and the bulb middle and right plates in the right duct CAUTION W...

Page 19: ...this method on cold glass or on warm glass with a glove 2 With a damp cloth and wood ash The window can be easily cleaned with a cloth or slightly damp absorbent paper that has been previously soaked...

Page 20: ...which makes force the engine which can burn or make noise Before any work please disconnect the electricity supply The fan can be dusted if it is fouled Do not apply pressure to the fan blades at the...

Page 21: ...powerfull V M C or cooker extraction hood During the opening of the door Consult the installer Draft test with a depression meter Inspect the flue and sweep if necessary Review the air intake level of...

Page 22: ...the position of the baffle Check the position and seal of the door joints The window fouls very quickly Damp wood Slightly insufficient draft Operating with the primary air not sealed Burn rate reduc...

Page 23: ...yal association of Belgian gas fitters meeting the European EN 13229 A2 standard it was stated that The power in kW for Pure 58 6 to 8 kW Pure 67 8 to 10 kW Pure 77 9 to 11 kW Pure 77 XL 11 to 13 kW P...

Page 24: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018 24 CE MARKING...

Page 25: ...livery by the installer or dealer for the following parts the combustion chamber body of the appliance and the external trim The warranty is limited to two years for the following parts the fans the a...

Page 26: ...ssary calorific supply Poor choice of fuels Overload of the fireplace with wood with respect to the permitted limits Intentional and permanent interruption of the ventilation By agreement the costs of...

Page 27: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018 27 Stick your identification plate here...

Page 28: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018 28 NOTES...

Page 29: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be PURE EN June 2018...

Reviews: