![Jide PURE 58/47 Manual For Installation, Use And Maintenance Download Page 23](http://html1.mh-extra.com/html/jide/pure-58-47/pure-58-47_manual-for-installation-use-and-maintenance_4025330023.webp)
Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
PURE (EN) June 2018
23
DECLARATION OF CONFORMITY JIDÉ
We hereby certify that the following appliances comply with the type model described in the declaration of
conformity CE. They are manufactured and launched in accordance with the requirements specified in the
royal decree of 12th October 2010, regulating minimal standards for performance and level of pollutant
release for heat appliances fired by solid fuel.
PURE – intermittent appliances
According to the test report issued by the A.R.G.B. laboratories (Royal association of Belgian gas-fitters)
meeting the European EN 13229/A2 standard, it was stated that:
The power in kW for:
Pure 58 ............................................................................................................................................ 6 to 8 kW
Pure 67 .......................................................................................................................................... 8 to 10 kW
Pure 77 .......................................................................................................................................... 9 to 11 kW
Pure 77 XL .................................................................................................................................. 11 to 13 kW
Pure 70 .......................................................................................................................................... 9 to 11 kW
Pure 16/9 ..................................................................................................................................... 11 to 13 kW
Efficiency measured and calculated according to standard is 77 % and 80,2 % for Pure 77 XL.
Carbon monoxide emissions measured according to standards is 0.08 %.
Particle emissions measured according to standards is 38 mg and 24 mg for Pure 77 XL
In order to guarantee the good working of the appliance and not to release pollutants dangerous for health
and environment in the atmosphere, we strongly recommend to follow the guidelines concerning advised
and not advised fuel, stated in the instruction manual supplied with the appliance.
Herve, the 14/06/2018
Vincent HICK