JIANGYIN TITANERGY TT-ADJUSTABLE TILT LEGS Installation Manual Download Page 7

5

.

Components Description

Published Date 2015-10-20            7 / 21

JIANGYIN TITANERGY CO.,LTD.

Phone:0086-510-86610879        
F a x : 0 0 8 6 - 5 1 0 - 8 6 6 1 0 8 7 7
W e b : w w w. t i t a n e r g y. c o m          
M a i l : i n f o @ t i t a n e r g y. c o m

T

-

T Rail

 

 

  hold

 

each panel

 

row

 

  length

 

can

 

be customized

 

  6005

-

T5

 

extruded

 

aluminum

 

 

Standard

 

Rail

 

Length

 

808

~

826mm wide

 

panels

 

990

~

1020mm wide panels

 

2560mm (3 panels)

 

 

3405mm (4 panels)

 

4200mm (4 panels)

 

 

TT

 

Rail

 

Splice

 

Kit

 

  Extend TT Rail

 

to

 

any length

 

as required

 

by

 

the

 

quantity or width

 

of the

 

solar

 

panels

 

Inter Clamp Kit for Framed Modules

  Fit

 

between

 

two

 

panels

 

 

Front Leg

Rear Leg

Bolts& Nuts

 

 

  Fastened with

 

a

 

6mm Allen key

 

  Standard

 

pre

-

assembly for

 

the

 

usual

 

panels

 

with

thickness 30, 35, 40, 46, 50

57mm

 

 

End

 

Clamp

 

Kit

 

for

 

Framed

 

Modules

 

  Hold the edge

 

of each end

 

panels 

 

  Fastened with

 

a

 

6mm Allen key

  Standard

 

pre

-

assembly for

 

the

 

usual

 

panels with

 

thickness 30, 35, 40, 46, 50

57mm

 

Fit on the roof
Include 2pcs  st6.3*80 wood screws

 

 

 

Fit on the roof
Include 2pcs  st6.3*80 wood screws
Include 1pc M8*25 bolt,1pc M8 spring washer,
2pcs M8,OD18 lock washers,1pc nut,1pc M8*55 bolt,
4pcs flange nuts with M8 locking teeth,1pc M8*20 bolt,
1pc M8*15 bolt 

 

 

 

Model Name

TT-ADJUSTABLE TILT LEGS

Revision Number:01

  Include 2pcs M8*20 bolts,2pcs M8 spring washers,

2pcs  M8,OD18 lock washers

  Include 1pc M8 bolt,1pc M8 spring washer,1pc nut

  Include 1pc M8*25 bolt,1pc M8 spring washer,1pc nut 

Include 1pc M8*25 bolt,1pc M8 spring washer,
2pcs M8,OD18 lock washers,1pc nut,1pc M8*55 bolt,
1pc flange nut with M8 locking teeth

 

 

Include 1pc M8*25 bolt,1pc M8 spring washer,
1pc M8,OD18 lock washer,1pc nut

 

 


The installation direction of panels can be customized.(horizontal or vertical)

The length of TT-Rail can be customized.(1.05m~15.90m)

Summary of Contents for TT-ADJUSTABLE TILT LEGS

Page 1: ...JIANGYIN TITANERGY CO LTD SOLAR ROOF MOUNTING SYSTEM INSTALLATION MANUAL ModelName TT ADJUSTABLETILTLEGS...

Page 2: ...0 11 Chapter Page General Information Safety and Installer Responsibilities Technical Specifications Tools for Installation Components Description System Overview Designing The Module Field Planning I...

Page 3: ...ly So the D Modules is pre assembly with the clamp to save your install time Tilt in Align Up Fasten Easy installation four steps Titan solar s versatile design makes it suitable for a wide variety of...

Page 4: ...ll site taking into account roof shape and geographic location Sufficient guidance is given in this document but you may wish to procure a copy of these standards REMEMBER average wind speeds are high...

Page 5: ...04 635MPa 235MPa Stainless Steel A2 70 700MPa 450Mpa 3 4 Installation condition Roof slope 0 to 60 Building height Up to 20m Mounting structure Timber Roof type Flat steel System angle Flushed with th...

Page 6: ...fixings Angle grinder For terracotta tile roof installation and angle grinder fitted with a continuous edge diamond tipped tile0cutting blade gloves hearing protection a face protection mask and a sui...

Page 7: ...Fastened with a 6mm Allen key Standard pre assembly for the usual panels with thickness 30 35 40 46 50 57mm Fit on the roof Include 2pcs st6 3 80 wood screws Fit on the roof Include 2pcs st6 3 80 wood...

Page 8: ...Screw Grounding Lug Fix the wire Material Cu Include 1pc M8 25 bolt 1pc M8 spring washer 1pc M8 OD18 lock washer 1pc nut 1pcM6 15 bolt Grounding Clip Electric Conduction Material Stainless steel Rubb...

Page 9: ...1 2 of module height 4 Distance between roof connections horizontally Depending on the distance between rafters and on the static requirements please see the Chapter 8 on page 11 5 Distance between m...

Page 10: ...on 8 3 Determine Roof Installation Roof Areas Titan solar system can be installed anywhere on a roof but fixing centers are required to be reduced at ridges and edges The diagram below shows the area...

Page 11: ...nD Please use the following table to determine the base rail support spacing for for tin roof installations 2 Max PV panel length 2000mm Max panel weight 15kg m Tin Roof 10 a 15 Adjustable Racking Til...

Page 12: ...or Up To 1970mm Long Panel 2Rails Max Support Spacing mm Installation Region A RegionB RegionC RegionD Height m Center Center Center Edge Center Edge Edge Edge Tin Roof 10 a 15 Adjustable Racking Tilt...

Page 13: ...5 N A N A 20m 950 675 650 475 400 300 N A N A 5 m 1125 800 775 550 475 325 300 N A 10 m 925 675 625 450 425 300 N A N A 15m 850 600 575 425 375 N A N A N A 20m 800 575 550 375 325 N A N A N A Note for...

Page 14: ...1200mm between the feet and 600mm of overhang at each end 8 6 Determine Roof Slope Titan solar system can be used for roof slope up to 60 degrees Please verify the Installation site roof slope should...

Page 15: ...Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail info titanergy com 9 Installation 2 Fix the rear leg together with rubber pad to the rafter using two 6 80 wood screws Determin...

Page 16: ...sher M8 antiskid washer and fixing nut to connect the rail with the front leg and the rear leg 4 TT Rail connect a Put the Rail Splice into the TT side channel of the Rail about TT 75mm then fasten th...

Page 17: ...of rails 5 Repeat the above steps in accordance with the planned layout Telescopic Tubs 6 After finishing installation of whole system adjust the lengths of rear legs to adjust the tilt angle of panel...

Page 18: ...Inter module clamp firmly against the already fixed module c Push the next module against the other side of the module inter clamp d Tighten the bolt 11 Installing the further rows of modules 9 Fixin...

Page 19: ...e zip tie Published Date 2015 10 20 19 21 JIANGYIN TITANERGY CO LTD Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail info titanergy com Model Name TT ADJUSTABLE TILT LEGS Revis...

Page 20: ...ng system Purchaser or where the Purchaser is an installer or builder who on supplies the Frame to another party to that other party End User This warranty is not transferable Where an End User wants...

Page 21: ...Reason for change Document Author 01 2015 10 20 Initial Release Josie Published Date 2015 10 20 21 21 JIANGYIN TITANERGY CO LTD Phone 0086 510 86610879 Fax 0086 510 86610877 Web www titanergy com Mail...

Reviews: