10
Water Drainage
This machine with auto-water-evaporating system. Condensed-water cycle to
cool down the condenser, which will not only improve cooling efficiency, but also
save energy.
●
If inner water tank is full, “
” will flashed on the screen , machine enter into standby mode,
buzzer shouts , compressor stops and all keys is invalid till machine recovers to be normal .
●
Pull out the plug to drain out water, power off the machine and restart it , the machine will runs
normally .
Maintenance
Note: in order to avoid electric shocks, please power-off the machine and pull out
plug before maintenances or repairs.
Cleaning
●
Please pull out plug before cleaning .
●
Use soft semi-dry cloth to clean the machine. Don’t use chemical agents, such as benzene,
alcohol, gasoline and so on ; otherwise the machine surface will be damaged, or even the
machine itself.
●
Don’t spatter water into the machine .
Filter
●
Clean the filters every two weeks, if filters are blocked by dust, machine efficiency will be
reduced .
●
Clean the filters in warm water with neutral detergent, then dry the cleaned filters on a shady
place.
Note
:
Don’t run the machine without filters.
Season Cleaning
If the machine will be unused for a long time, please do as following :
●
Pull out drainage plug upper / lower to flow out water.
●
Let the machine runs under fan mode for 2 hours to dry out the machine internal
●
Turn off machine and pull out plug .
●
Clean and dry filters , then reinstall them .
●
Pull out exhaust pipe for safekeeping .
●
Put the machine into plastic bag , and place it on a dry place.
Summary of Contents for A002BPY-18KR/A