JF-Airclean E-BG-06 Operating Manual Download Page 6

6

1.4

Implement the standards

1.G B 4706.1

Safety for household and similar appliances

Part 1: General

requirements
2. Disinfection Technical Specification, 2002 Edition

1.5

Equipment function introduction

The disinfection staff will install the disinfection machine in the supporting
disinfection environment area, and measure the spatial volume of the area
requiring disinfection. After entering the spatial volume, the equipment
automatically starts the spray. The general disinfection time of the object surface is
5 minutes and the air disinfection time is 30 minutes.

1.6.1

Working principle

[Disinfection principle]

The equipment adopts the atomization principle of ultrasonic disinfection, using
hypochlorite acid as the original liquid, and it is injected continuously into the
space through spray, which changes the microbial protein and genetic material on
the surface of the air, so as to achieve the purpose of disinfection.

[Disinfection process]

It into preparation, spray and action time.

Summary of Contents for E-BG-06

Page 1: ...Directory 1 Producer Health License No ZZ 2019 No 0108 Wall mounted UAD01 type digital atomization disinfection machine Operating manual ...

Page 2: ...6 2 Scope of application 7 1 6 3 Main functions and features 7 1 6 4 Use Method 7 1 6 5 Service life 11 1 6 6 Disinfection solution description 11 1 6 7 Transport and Storage 12 Chapter II matters needing attention 13 2 1 matters needing attention 13 Chapter III Daily maintenance 14 3 1Shutdown 14 3 2Clean it up 14 Chapter IV Faults and Solutions 15 4 1 Troubleshooting 15 Chapter V Appendix 16 5 1...

Page 3: ...norovirus and other pathogenic bacteria Power supply supply AC 220V 50HZ Eliminati on efficienc y Air disinfection killing rate 99 99 and object surface disinfection killing rate 99 99 Foatomize d particles 5 7μm deodorodo reffect Perchloric acid can effectively remove the odor produced by sulfur dioxide ammonia propionic acid and other chemicals and can be used for toilet deodorization livestock ...

Page 4: ...eight approximately 8 4kg Disinfect ion scheme Spray rate 50ml min General object surface disinfection action time is 5 minutes air disinfection action time is 30 minutes Managemen t system The disinfection parameters can be local or remote one key to start the disinfection data can be checked 1 3 Equipment appearance and structure ...

Page 5: ...5 ...

Page 6: ... the spatial volume the equipment automatically starts the spray The general disinfection time of the object surface is 5 minutes and the air disinfection time is 30 minutes 1 6 1 Working principle Disinfection principle The equipment adopts the atomization principle of ultrasonic disinfection using hypochlorite acid as the original liquid and it is injected continuously into the space through spr...

Page 7: ...integrity 4 Support the remote connection of the mobile phone WeChat applet 5 Unattended timing mode 6 Liquid addition reminder and liquid deficiency protection 1 6 4 Use the method Volume Mode Install the wall mounted digital atomization disinfection machine hereinafter referred to as the disinfection machine in the area to be disinfected turn the power on and fully measure the volume placed in t...

Page 8: ... the hours and minutes you want disinfection click to start disinfection the equipment can automatically start the spray work Smart Mode 1 can set the local start time of a single disinfection 2 can set circular disinfection mode only daily 3 can set up three work tasks locally ...

Page 9: ...infection report can be uploaded to the mobile phone end and the disinfection start time disinfection end time and disinfection mode setting can be inquired Alert and alarm No ial Reminder content Light The Sound Display Remote Note ALM 1 Standby Green in color None Display the main interface Standby status ALM 2 Working normally Yellow color None Displays the disinfectio n mode and the countdown ...

Page 10: ...nder interface Reminde r of low water level ALM 5 Solution deficienc y The red light flashe s The buzzer is often ringing Defid reminder interface Reminde r of fluid shortag e Stop disinfectio n until alarm ALM 6 Failure The red light always lights on The buzzer is often ringing Failure reminder interface Failure reminde r Stop disinfectio n until alarm ALM 7 Tt The red light always lights on The ...

Page 11: ...on The disinfectant machine uses hypochlorite disinfectant and the validity period is 24 months In order to ensure the disinfection ability of the disinfectant machine do not change the disinfectant model at will The disinfectant manufacturer is the following the original liquid is not diluted and used directly ...

Page 12: ...intain the normal discharge of container pressure Should not be transported in rainy days It shall be stored separately from flammable or combustible substances reducing agent sulfur and phosphorus and avoid mixed storage and transportation Avoid contact with other substances that can easily cause product decomposition Avoid product contact with the eyes skin and clothing Keep the ambient air smoo...

Page 13: ...o not skew and install it horizontally 2 3 If the power cord is damaged the manufacturer must be replaced by the repair professionals in order to avoid danger 2 4 This product is not suitable for persons children and people with disabilities mental disabilities or mental disabilities unless under the care or guidance of the person responsible for their safety 2 5 Do not plug the air outlet otherwi...

Page 14: ...w and miscellaneous bacteria reproduction Important Safety instructions for the operation and maintenance of the disinfection machine are described in the precautions of this instruction Do not operate the device without reading the safety precautions 3 2 Clean it 1 In order to ensure cleaning the disinfection machine can be cleaned according to the ordinary equipment use a rag to save the right a...

Page 15: ...infection machine can not be turned on Check whether the power plug is properly connected Check the power supply for power supply 2 Touch screen operation fails Try the power switch to restart the terminal 3 The mobile terminal cannot get the disinfectant machine information Check whether the network connection is normal ...

Page 16: ...uction problems you can get free warranty or replacement 2 Any fault or damage caused by improper user operation unauthorized repair or modification and taking the operation or falling against the use instructions shall not be within the warranty 3 5The warranty period is 1 year starting from the purchase date of the equipment ...

Reviews: