![Jevi DELTA 3000 Instruction Manual Download Page 6](http://html1.mh-extra.com/html/jevi/delta-3000/delta-3000_instruction-manual_3919736006.webp)
GB
Fan Heaters
(Original instruction)
General for A + B
Permanent Installation (fixed) The
heater can be installed horizontally
or at a downward gradient of 15°.
Operation panel must be visible from
1 meter distance.
1. The fixings are attached to the
housing by use of 4 screws. The two
spacing washers are placed between
the housing and tubular frame (in the
bottom hole).
2. Mark the hole positions. Drill out
4 holes to attach the fixing to the
wall. Use M8 screws.
3. Now fix the heater in the top
screws and attach the bottom
screws.
Use of DELTA - List of signs
Off
Fan on
Half fan and half heat
Full fan and half heat
Full fan and full heat
DELTA fan heaters require no
maintenance. However, it is
recommended to clean the fan
heater from dust by means of
compressed air after long time of use
or after use in dusty rooms.
Timer
To set time delay, rotate the knob
clockwise and then turn back
anticlockwise to required setting
Electrical Installation
Installation must be carried out with
an all-pole disconnection with a
contact space measuring at least
3 mm per pole. Permanent
installation must always be
performed by an authorized
electrician in accordance with current
regulations. Only the electrician has
knowledge of current regulations.
The terminals are accessible if the
screws and the plate on the right
side are removed.
Preservation and storage
The units must be stored under the
following conditions:
• relative humidity maximum 60%
• temperature minimum 15°C
Summary of Contents for DELTA 3000
Page 19: ...BG 1 m 8 3 3 8 3 8...
Page 21: ...BG A B 15 1 1 4 2 4 8 3 DELTA DELTA 3 mm 60 15 C...
Page 23: ...BG...
Page 59: ...RU 1 8 3 3 8 3 8...
Page 61: ...RU B C A B 15 1 1 4 2 4 M8 3 DELTA DELTA 3 60 15 C...
Page 63: ...RU...
Page 79: ......