background image

Measurement and instrumentation 

EVOLIO F15 ± / 0.4 A power supply 

Ref : 
281 002 

ENGLISH

 5 

 

 

1 Description 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1 – Plastic box with double insulation 

2 – On/off switch 

3 – Operating indicator 

4 – -15, 0, +15 V outputs on safety sockets 

2 Setting 

up 

 

Connect the power supply to the 230 V mains supply. 

 

Toggle the master switch so that the power-on indicator lamp comes 

on. 

  Connect your circuit (lamp, motor, voltage divider, etc.) to the 

selected output sockets. 

Notes 

If the current flow on the output used is greater than the maximum 
permissible value (0.4 A), the current remains at about 0.4 A and the voltage 
gradually reduces. Remove the source of the overload or the short circuit to 
return to normal operation. 

1

Summary of Contents for EVOLIO F15 /0.4 A

Page 1: ...Mesures et instrumentation Measurement and instrumentation Ref 281 002 Fran ais p 1 English p 5 Version 8010 Alimentation EVOLIO F15 0 4 A EVOLIO F15 0 4 A power supply...

Page 2: ...der votre circuit lampe moteur diviseur de tension sur les douilles de la sortie s lectionn e Remarque Si le courant d bit sur la sortie utilis e est sup rieur au maximum autoris 0 4 A le courant rest...

Page 3: ...VA Protection primaire fusible calibr sur C I secondaire lectronique Dimensions 115 x 140 x 80 mm Masse 950 g Garantie 2 ans Cet appareil est conforme La directive Basse Tension 73 23 CEE norme appliq...

Page 4: ...ne fonctionne toujours pas contacter le Service Apr s Vente Dans tous les cas ne pas ouvrir l appareil Le changement du fusible secteur doit tre fait dans nos ateliers Conserver l emballage d origine...

Page 5: ...Mesures et instrumentation Alimentation EVOLIO F15 0 4 A Ref 281 002 FRAN AIS 4 NOTES...

Page 6: ...upply to the 230 V mains supply Toggle the master switch so that the power on indicator lamp comes on Connect your circuit lamp motor voltage divider etc to the selected output sockets Notes If the cu...

Page 7: ...each output Stabilisation 1 Residual ripple Less than 10 mV Power supply 230 V 10 50 60 Hz Power consumed from the mains 30 VA Protection Primary fuse calibrated on I C Secondary electronic Dimensions...

Page 8: ...ing any load If the device still does not work contact the After Sales Service In all cases do not open the device Replacing the mains fuse must be done at our workshops Store the original packaging i...

Page 9: ...Measurement and instrumentation EVOLIO F15 0 4 A power supply Ref 281 002 ENGLISH 8 NOTES...

Page 10: ......

Reviews: