31
WatchDog Reset Timer
Use this item to enable or disable WDT reset function.
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Value
User can select a value in the range of [10] to [255] seconds when ‘
WatchDog
Reset Timer Unit
’ set as
[Sec]
; or in the range of [1] to [255] minutes when
‘
WatchDog Reset Timer Unit
’ set as
[Min]
.
WatchDog Reset Timer Unit
The optional settings: [Sec.]; [Min.].
WatchDog Wake-up Timer
This item support WDT wake-up.
The optional settings: [Enabled]; [Disabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Wake-up Timer Value
User can select a value in the range of [10] to [4095] seconds when ‘
WatchDog
Wake-up Timer Unit
’ set as
[Sec]
; or in the range of [1] to [4095] minutes when
‘
WatchDog Wake-up Timer Unit
’ set as
[Min]
.
WatchDog Wake-up Timer Unit
The optional settings: [Sec.]; [Min.].
ATX Power Emulate AT Power
This item support Emulate AT power function, MB power On/Off control by power
supply. Use needs to select ‘AT or ATX Mode’ on MB jumper at first
(refer to
ATX_AT jumper
setting for ATX Mode & AT Mode Select).
Serial Port Console Redirection
COM1
Console Redirection
The optional settings: [Disabled]; [Enabled]. When set as [Enabled], the following
sub-items shall appear: