Change oil in pump after first 50 hours of operation and 
every 500 hours of operation after that. With the pump 
warm from operation, remove plug on bottom of pump 
and drain oil into suitable container. Replace plug. Fill to 
approximately half-way on the sight-glass with SAE 15W-
40 Mineral non-detergent oil using the checking procedure. 
Approximately 1000 ml of oil are required to change the 
pump oil.
At 1000 hours of use (less in severe use conditions) the 
Scorpion G2 should be taken to a Jetwave Independent 
Service Center for pump seal and valve service.

Gearbox Lubrication

Check the gearbox oil level prior to each use. Place the 
jetter on a level surface. Wipe any dirt and debris from 
the area of the dipstick and sight-glass (Figure 16). Oil 
level should be at the middle of the sight-glass. If needed, 
remove the dipstick and add SAE 85W-140 gear lubricant 
oil, fill to half-way on the sight-glass. Do not overfill, reinstall 
dipstick.
Change oil in gearbox every 500 hours of operation. With 
the gearbox warm from operation, remove plug on bottom 
of gearbox and drain oil into suitable container. Replace 
plug. Fill to half-way on the sight-glass with SAE 85W-140 
gear lubricant oil. Approximately 300 ml of oil are required 
to change the gearbox oil.

Preparing Pump for Cold Weather Storage

If the jetter will be stored under conditions where the 
temperature is near or below 0°C, the jetter must be 
properly prepared. If water freezes in the pump, it can 
damage it.
After the tank is drained, remove the hose from the 
water inlet filter. Open all valves in the system and use 
compressed air to force any water out of the system. This 
can also be used to remove water from the hoses.

Machine Storage

Store the jetter in a well ventilated area protected from rain 
and snow. Keep the machine in a locked area that is out 
of reach of children and people unfamiliar with Jetters. This 
machine can cause serious injury in the hands of untrained 
users. See Maintenance section for information on cold 
weather storage. See engine operator’s manual for specific 
information on engine storage.

Service And Repair

WARNING

Improper service or repair can make machine unsafe 
to operate.

The “Maintenance Instructions” will take care of most 
of the service needs of this machine. Any problems not 
addressed by this section should only be handled by an 
authorized Jetwave service technician.
Tool should be taken to a Jetwave Independent Service 
Center or returned to the factory.
For information on your nearest Jetwave Independent 
Service Center or any service or repair questions:
•  Contact your local Jetwave distributor.
•  Visit jetwavegroup.com.au/find-a-dealer/ to find your 

local Jetwave contact point.

•  Contact Jetwave Technical Service Department at 

[email protected] or call (08) 8371 3599

Disposal

Parts of the water jetter contain valuable materials and 
can be recycled. There are companies that specialize 
in recycling that may be found locally. Dispose of the 
components in compliance with all applicable regulations. 
Contact your local waste management authority for more 
information.

Summary of Contents for Scorpion G2

Page 1: ...duct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure...

Page 2: ...ne and Work Area Set Up Water Supply Drain Preparation Hose Set Up Jetter Hose Selection Chart Jetter Nozzle Selection Chart Operating Instructions Jetting the Drain Draining Water from System Using W...

Page 3: ...fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive atmosphe...

Page 4: ...ator must be able to shut off the water flow to reduce the risk of the jetter hose whipping causing striking and high pressure injection injuries Always use appropriate personal protective equipment w...

Page 5: ...Jetting Machine is a portable high pressure water jetter designed to use a combination of water pressure and flow to clear grease sludge sediment and roots out of drains A highly flexible and lightwe...

Page 6: ...arbox Check oil level ensure half way on sight glasses per Maintenance section Pre Operation Inspection WARNING Before each use inspect your water jetter and correct any problems to reduce the risk of...

Page 7: ...et up the jetter and work area according to these procedures to reduce the risk of injury from high pressure water chemical burns infections carbon monoxide and other causes and prevent jetter damage...

Page 8: ...m water use appropriate personal protective equipment to reduce the risk of burns When using in cold weather use precautions to prevent water from freezing in the pump This can damage the pump Drain P...

Page 9: ...cifically sized for the jetter being used Using incorrect nozzles can cause poor performance low operating pressure or low flow or may damage the jetter with excessively high pressures Make sure the n...

Page 10: ...er pipes 3 to 4 with tighter radiuses bends This nozzle is smaller in size and eliminates the quick connect to allow easier negotiation around bends in the line It has three rear jets with one facing...

Page 11: ...s and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators and steel toed footwear Follow operating instructions to reduce the risk...

Page 12: ...n control the ON OFF action of a water control valve ball valve or foot valve Do not turn the valve ON yet In case of emergency you must be able to turn off water flow Be sure that you have good balan...

Page 13: ...a pressure washer is similar to use as a jetter and those instructions should be used in conjunction with the following 1 Locate an appropriate work area 2 Make sure all equipment has been properly i...

Page 14: ...ways wear safety glasses and gloves when performing any maintenance to help protect against drain chemicals and bacteria Cleaning The hose should be cleaned as needed with hot soapy water and or disin...

Page 15: ...epared If water freezes in the pump it can damage it After the tank is drained remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out o...

Page 16: ...through each orifice to remove debris Remove nozzle and insert jet hose in drain line Run jetter to flush trapped air or debris Jetter won t start Not enough water in the tank Filter is clogged See J...

Page 17: ...17 SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 18: ...SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER 18 NOTES...

Page 19: ...19 SCORPION G2 MANUAL WATER JETTER DRAIN CLEANER NOTES...

Page 20: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group...