background image

 

 

Edition 1.00 

March 2003 / Printed in Germany 

 

 

 

 

 

NANO-C 

Version Update 

from V3.00 to V3.01 

 

 

 

 

Summary of Contents for NANO-C

Page 1: ...Edition 1 00 March 2003 Printed in Germany NANO C Version Update from V3 00 to V3 01...

Page 2: ...hese alterations need not be documented in every single case This manual and the information contained herein have been compiled with due diligence However Jetter AG assumes no liability for printing...

Page 3: ...4 Access to JX SIO analog values 11 2 4 Monitoring the activities of interfaces 12 2 4 1 Register for monitoring the activities of interfaces 13 2 4 2 Special flag for monitoring the activities of int...

Page 4: ...been integrated Function and Power Level Terminals JX SIO P P LCD PC and JETWay Interface Monitoring P P User Interfaces No Data Error After Power On P Networking via JETWay P P V3 00 System bus P P S...

Page 5: ...e text For diverting the display instructions onto the Prim interface device 9 must be selected For diverting the display instructions onto the JX2 SER1 expansion module device 11 must be selected The...

Page 6: ...X SIO module The following modules are supported by a NANO C of the software version 3 01 Further modules at the system bus Manufacturer Product Designation B rkert GmbH Co KG Valve terminal type 8640...

Page 7: ...ption IN 7000 IN 7999 digital inputs of further modules OUT 7000 OUT 7999 digital outputs of further modules Reg 5000 Reg 5999 I O register overlay of digital and analog inputs Reg 6000 Reg 6999 I O r...

Page 8: ...9 2 3 1 2 Module Array All further modules that have been recognized will be stored in the module array by an unambiguous code The module array can be accessed via registers 2015 and 2016 Register 20...

Page 9: ...NT1 6 JX2 PRN1 7 JX2 SER1 JX SIO and further modules 64 JX SIO 65 Festo CPV Direct 66 Festo Terminal CPX 67 Buerkert valve terminal type 8640 SMC SI unit EX12 SCA1 JX2 slave modules 128 JX2 SV1 129 CA...

Page 10: ...e JX SIO IB IL 400 MLR 1 8A IB IL 400 ELR 1 3A IB IL 400 ELR R 3A INLINE CAM by Deutschmann Automation GmbH JX SIO Function Terminals Register Survey Register Number Description 7x04 Index of function...

Page 11: ...not active 2272 Access to an unknown JX SIO register 2273 Access to a register which is not supported by this JX SIO e g configuration of an analog input although there is no analog input terminal 227...

Page 12: ...sed As the second special flag has not been set by the operating system the user can check whether the connection had been interrupted for a short time In this case the NANO C would after an interrupt...

Page 13: ...g Register 2957 Monitoring time of the LCD interface Function Description Read present monitoring time in milliseconds Write new monitoring time in milliseconds Note Monitoring the interface activity...

Page 14: ...ors on the LCD interface Note The error count is not supported if PRIM interfaces are used Write reset the error counter Value range 0 65535 Value after reset 0 Each time a character has been received...

Page 15: ...operating system flag 0 no valid telegrams 1 the interface is active 2091 PC interface user flag 0 no valid telegrams to be set by the user 2092 operating system flag 0 no valid telegrams 1 the interf...

Page 16: ...width set in register 2812 Field width for the display of interregisters Up to version 3 00 10 characters would always be edited 3 3 Network Operation The NANO C will only accept a token in a JETWay...

Reviews: