JX2-IO16
5.1 General Information
Jetter AG
29
5
Technical Data
5.1
General Information
Technical Data - General
Module Code
2
Rated voltage of logic circuit
DC 24 V, max. ripple 5%
Operating voltage range of logic
circuit and sensor supply
DC 20 .. 30 V
No-load current of logic circuit at
X10.0,05A.DC24V (without other
JX2-IO modules)
≤
40 mA
Heat loss of logic circuit
≤
1.2 watt
Maximum current consumption at
X10.0,0,05A.DC24V when
supplying additional 3 JX2-I/O
modules.
135 mA (45 mA per JX2-IO module)
Maximum total current consumption
at X10.0,05A.DC24V for supplying
sensors.
1.6 A (8 x 200 mA)
Maximum total current consumption
of all outputs at X10.4A.DC24V
4 A (8 x 0.5 A)
Maximum total current consumption
of the module
5.775 A
Maximum rated power loss (total)
140 Watt
Connection to the basic unit via
system bus
System bus cable connected to SUB-D, 9
pins
Housing bottom
Aluminium, powder coated;
Colour: Blue
Housing cover
Steel sheet metal coated with AlZn
Dimensions (H x W x D in mm)
103 x 130 x 48
Weight
350 g
Installation
DIN-rail EN 50022-35 x 7.5
Summary of Contents for JX2-IO16
Page 10: ...Table of Contents JetWeb 10 Jetter AG...
Page 18: ...1 Safety Instructions JetWeb 18 Jetter AG...
Page 22: ...2 Introduction JetWeb 22 Jetter AG...
Page 23: ...JX2 IO16 Jetter AG 23 3 Mounting Dimensions Fig 3 Front View JX2 IO16 Fig 4 Side View JX2 IO16...
Page 24: ...3 Mounting Dimensions JetWeb 24 Jetter AG Fig 5 Top View JX2 IO16...
Page 56: ...6 Installation Guide JetWeb 56 Jetter AG...
Page 68: ...9 Fast inputs Software filter JetWeb 68 Jetter AG...
Page 82: ...10 Pulse stretching JetWeb 82 Jetter AG...
Page 105: ...JX2 IO16 Appendix Jetter AG 105 Appendices...
Page 106: ...Appendices JetWeb 106 Jetter AG...
Page 123: ...JX2 IO16 Appendix Jetter AG 123...